Standard Values Of The Parameters - Emerson Dixell XB Series Installing And Operating Instructions

Blast chiller
Table of Contents

Advertisement

Cy4: direct fast freezing without holding
CyS = tEP
dbC = no
iS1 =-18°C (0°F)
rS1=-30°C (-22°F)
Pd1 = 4.0

20. STANDARD VALUES OF THE PARAMETERS.

Lab Description
Set
Set point
Hy
differential
AC
Anti-short cycle delay
PAU Time of stand by
PFt Maximum acceptable duration of power failure
Con Compressor ON time with faulty probe
COF Compressor OFF time with faulty probe
rPO Thermostat probe calibration
EPP Evaporator probe presence
EPO Evaporator probe calibration
i1P
Insert probe 1 presence
i1o
Insert probe 1 calibration
i2P
Insert probe 2 presence
i2o
Insert probe 2 calibration
i3P
Insert probe 3 presence
i3o
Insert probe 3 calibration
rEM Probe selection to stop chilling cycle
CF
Temperature measurement unit
rES Resolution (for °C):
Lod Local display
rEd Remote display
d1P Door switch polarity
Odc Open door control
dOA Open door alarm delay
dLc Stop count down of running cycle
rrd
Regulation restart after door open alarm
d2F Second digital input function
d2P Second digital input polarity
did
Time delay for digital input alarm
oA1 First configurable relay function
oA2 Second configurable relay function
oA3 Third configurable relay function
2CH Compressor setting during the holding
OAt Second compressor switching on delay
OAS Set point for second compressor
OAH Differential for second compressor
OAi Probe selection for second compressor
OSt Auxiliary output timer
OSS Set point for auxiliary output
OSH Differential for auxiliary output
OSi Probe selection for auxiliary output
tdF
Defrost type
idF
Interval between defrost cycles
dtE
Defrost termination temperature
MdF Maximum length for defrost
dFd Temperature displayed during defrost
Fdt
Drip time
dAd Defrost display time out
FnC Fan operating mode
1592006207 XB570L GB r1.1 23.03.2015
iS2=-18°C (0°F)
rS2=-30°C (-22°F)
Pd2 =OFF
iS3=-18°C (0°F)
rS3=-30°C (-22°F)
Pd3 = OFF
dbH = no
HdS = OFF
Values
XB570L
Level
3.0
- - -
2.0
Pr1
1
Pr2
0
Pr2
15
Pr2
15
Pr2
10
Pr2
0.0
Pr2
YES
Pr2
0.0
Pr2
YES
Pr2
0.0
Pr2
n
Pr2
0
Pr2
n
Pr2
0
Pr2
iPt
Pr2
°C
Pr2
dE
Pr2
rP
Pr2
rP
Pr2
cL
Pr2
F-C
Pr2
5
Pr2
y
Pr2
Y
Pr2
EAL
Pr2
cL
Pr2
5
Pr2
tMr
Pr2
ALL
Pr2
Lig
Pr2
C1
Pr2
3
Pr2
0
Pr2
2,0
Pr2
rP
Pr2
0
Pr2
0
Pr2
2.0
Pr2
rP
Pr2
rE
Pr2
6.0
Pr2
8
Pr2
20
Pr2
rt
Pr2
0
Pr2
20
Pr2
c_n
Pr2
17/20