Tap Adjustment; Affix Label; Pressure Testing; Lubrication Of The Gas Taps - Rangemaster ECL75HPNGFBL/BL User Manual & Installation & Service Instructions

Gas on glass hob
Table of Contents

Advertisement

WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
Fig. 6.3
A

Tap Adjustment

Disconnect from the electricity supply.
When changing from one type of gas to another, the
minimum tap output must also be correct, considering that
in this position the flame must be about 4 mm long and must
remain lit even when the knob is turned sharply from the
maximum to the minimum position.
The adjustment is performed with the burner lit, as follows:
Turn the knob to the minimum position.
1.
Remove the tap knob.
2.
Turn the screw "A" to the correct setting (Fig. 6.3).
3.
For LPG, tighten the adjustment screw completely.

Affix Label

Stick the LP gas label over the natural gas part of the
appliance data label.

Pressure Testing

Make sure that the appliance is gas sound.
The gas pressure can be measured at one of the hotplate
burner injectors (not the Wok burner). Lift off a burner head.
Fit the pressure gauge to the injector. Turn on and light one
of the other hotplate burners. Turn on and push in the control
knob for the burner with the pressure gauge fitted to let gas
through.
Refer to the "Connections" table in the "Technical Data" for
pressure settings
Turn off the burners. Reassemble burner top, making sure it is
reassembled in the correct way on the burner body.

Lubrication of the Gas Taps

The operations must be executed by a qualified technician.
n
n
IMPORTANT: All intervention regarding installation
maintenance and conversion of the appliance
must be fulfilled with original factory parts. The
manufacturer declines any liability resulting from
the non-compliance of this obligation.
14

Advertisement

Table of Contents
loading

Table of Contents