Advanced Settings
Advanced Setting Menu
SETTING DESCRIPTION
000
Touch Screen Controller - Firmware Version
001
Ceiling Controller - Hardware Version
002
Ceiling Controller - Firmware Version
003
Ceiling Controller - Macro Version
004
Recycle Temperature - Maximum
005
Recycle Temperature - Minimum
006
Temperature Set - Threshold
007
Temperature Set - Differential
008
Heat Transfer Speed - High
009
Heat Transfer Speed - Medium
010
Filter Used Percentage
011
Temperature - Roof Cavity
012
Temperature - Room
013
Screen Brightness - Maximum
014
Screen Brightness - Minimum
015
Boost Time
016
Filter Reset
1. If RECYCLE
is enabled and the roof cavity sensor reading goes above the maximum recyle temperature setting or goes below the minimum recycle
temperature setting, then recycle mode will activate.
2. If your roof cavity or room temperature readings are inaccurate, use these settings to calibrate them.
3. To reset the filter change 016 setting value to 10 and press SELECT
14
RANGE
N/A
N/A
N/A
N/A
20°C - 50°C
0°C - 20°C
0°C - 5°C
0°C - 20°C
0°C - 15°C
0°C - 15°C
0 – 100%
-5°C - 5°C
-5°C - 5°C
0-100%
0-100%
0 min – 60 min
0 - 100
.
DEFAULT
NOTE
N/A
N/A
N/A
N/A
30°C
1
5°C
1
1°C
5°C
5°C
2°C
0%
0°C
2
-0.5°C
2
80%
10%
20 min
0
3