Maintenance
Filter Replacement
The filter will require replacing when the ERROR CODE
- When replacing with a filter of the same type, go to FILTER RESET (setting 016) to reset the filter.
- Contact SmartVent on 0800 140 150 for more information on the other filter types available and the
replacement of your current filter type if required.
- The
alert will still be displayed if the filter is not installed correctly.
FILTER TYPE
F7
F7 Carbon
HEPA Carbon
Technical Specifications
TOUCH SCREEN CONTROLLER V1.5
Temperature Range
Display Resolution
Operating Voltage/Frequency
Switching Voltage
Switching Current
Sensing Element
Operating Temperature
Operating Humidity
Live Output Isolation
Output Control
Display
Approval
EMC Approval
Specifications are subject to change without notice
Contact:
0800 140 150
enquiry@smartvent.co.nz
PRODUCT CODE
FAN2093
FAN2277
FAN2278
Distributed by Simx Limited
PO Box 14347, Panmure, Auckland, New Zealand.
Technical Support (09) 259 1662 | e: sales@simx.co.nz | w: www.simx.co.nz
is displayed.
TYPICAL LIFE
12 months
6 months
6 months
5-35ºC adjustable
0.1ºC
220-240V AC, 50Hz
240V AC Max
3A max resistive load
NTC thermistor
0 to 40ºC
5-90% non condensing
Relay
Relay / 0-10V DC
3.5" digital LCD touch screen
All relevant AS/NZS standards
All relevant AS/NZS standards
PUB1522 2010