Gree GWH18AAC-K3NNA1A Service Manual page 34

Table of Contents

Advertisement

Service Manual
Zero-crossing
inspection
circuit
6
malfunction
of the IDU fan
motor
Lack of
refrigerant
or block
protection for
the system(not
7
applicable to
residential air
conditioner)
or Overload
protection
compressor
Installation and Maintenance
Operation of remote controller or control
U8
panel is available, but the unit won't act.
The Dual-8 Code Display will show F0
F0
and the complete unit stops.
1.Quick de-energization and energization. Wrong
judgement by the controller because the electric-
discharging of capacitor is slow.
2.Zero-crossing inspection circuit of main board for
controller is abnormal.
1.Refrigerant leakage;
2.Indoor evaporator temperature sensor works abnormally;
3.The unit has been plugged up somewhere;
4.The compressor can't be started up normally. Because
the power voltage for the complete unit is too low, and the
outdoor working condition is too high.
31