    Rev. 01-06/18 INDICE: 1. INTRODUZIONE p. 3 2. ISTRUZIONI DI SICUREZZA p. 4 3. APERTURA CONFEZIONE E CONTROLLO p. 6 4. INSTALLAZIONE ED ACCENSIONE p. 7 5. ISTRUZIONI PER L'USO p. 9 6. MANUTENZIONE p. 14 7. SPECIFICHE TECNICHE p. 14 INDEX: 1.
  • Page 3: Introduzione

    1. INTRODUZIONE Grazie per avere scelto un nostro prodotto! Vi preghiamo di fare riferimento alle istruzioni e alle avvertenze contenute nel presente manuale per l’utilizzo del dispositivo e di conservarlo per future consultazioni. Il presente manuale contiene informazioni riguardanti l’installazione e l’utilizzo del dispositivo.
  • Page 4: Istruzioni Di Sicurezza

    2. ISTRUZIONI DI SICUREZZA Attenzione! Questo prodotto non è adatto ad un uso domestico. Leggere il presente manuale prima di installare e dare corrente all’apparecchiatura, seguire le precauzioni di sicurezza elencate di seguito ed osservare tutti gli avvertimenti indicati nel presente manuale e stampati sull’apparecchiatura.
  • Page 5 CLASSE DI PROTEZIONE IP65 Il dispositivo è protetto dalla penetrazione di polvere (prima cifra 6) e da getti d’acqua (seconda cifra 5). Apparecchio adatto per uso esterno. PROTEZIONE CONTRO LE SCOSSE ELETTRICHE Il dispositivo deve essere collegato ad un sistema di alimentazione dotato di un’efficiente messa a terra.
  • Page 6: Apertura Confezione E Controllo

    Controllare che la scatola contenga i seguenti articoli: N° 1 SG SOLPARC60Z N° 1 Cavo di alimentazione N° 1 Cilindro antiabbagliamento N°...
  • Page 7: Installazione Ed Accensione

    4. - INSTALLAZIONE ED ACCENSIONE 4.1 - INSTALLAZIONE PRODOTTO - Non scuotere l'apparecchio. Evitare l'utilizzo di forza eccessiva durante le operazioni di installazione o fissaggio dell'unità. - L'unità può essere installata a pavimento in appoggio sugli appositi piedini, a parete, a soffitto o su truss.
  • Page 8 4.3 - COLLEGAMENTO ALLA CATENA DMX Utilizzare un cavo conforme alle specifiche EIA RS-485: bipolare intrecciato, schermato, 120Ohm di impedenza caratteristica e bassa capacità (SAGITTER SG DMX3 – SG DMX5). Non utilizzare cavo microfonico o altro cavo con caratteristiche diverse da quelle specificate.
  • Page 9: Istruzioni Per L'uso

    BLUE WhiteBal 50 - 255 WHITE TimeInfo Current (h) Info TimeInfo TotalTim (h) Informazioni ore di lavoro TimeInfo TimeInfo LastClea TimeInfo TimerPIN Info TempInfo Info TempInfo XXX °C Info SAGITTER Sol_P60 ModelInf Info 1U V103 Versioni software Software 2U V103...
  • Page 10 Info None/ZOOM Visualizzazione Errore Zoom ErrorInf Reset Zoom Rset.M ZOOM ZoomRset Calibrazione Zoom (password: 050) Calibrat 000-255 Slave Slave Modalità slave ManCtrl 000 - 255 Regolazione manuale Zoom ZOOM ManCtrl 000 - 255 Regolazione manuale Strobo Strobe ManCtrl 000 - 255 Regolazione manuale Rosso Manual ManCtrl...
  • Page 11 Tabella 1: programmi interni 1. STATIC R/G/B/RG/GB/RB/RGB/BLAC STR: 000-255 2. CHANG6 SP01-99 STR: 000-255 3. CHANG30 SP01-99 STR: 000-255 4. FADE SP01-99 STR: 000-255 Tabella 2: Lista macro Rosso Verde Bianco 001 - 004 005 - 008 009 - 012 013 - 016 017 - 020 021 - 024...
  • Page 12 133 - 136 137 - 140 141 - 144 145 - 148 149 - 152 153 - 156 157 - 160 161 - 164 165 - 168 169 - 172 173 - 176 177 - 180 181 - 184 185 - 188 189 - 192 193 - 196 197 - 200...
  • Page 13 5.3 - MODALITA' DMX Valore Funzione 000-255 000-255 000-255 000-255 000-255 Dimmer 000 - 015 LED On 016 - 031 LED Off 032 - 063 LED On 064 - 095 Strobo da lento a veloce 096 - 127 LED On 128 - 159 Pulse effect 160 - 191...
  • Page 14: Manutenzione

    6. - MANUTENZIONE Per garantire ottime prestazioni, l’apparecchio deve essere pulito frequentemente. Scollegare l’apparecchio della corrente e lasciarlo raffreddare per almeno 35 minuti onde evitare il rischio di bruciature. Utilizzare un’aspirapolvere o compressore e una spazzola morbida o un panno per lenti per rimuovere la polvere depositata. Le lenti, come qualsiasi altra parte eventualmente danneggiata, devono essere sostituite con ricambi originali.
  • Page 15: Introduction

    1. - INTRODUCTION Thank You for choosing one of Our products! Please refer to the instructions and warnings contained in this user manual, please retain it for future reference. This manual contains information about the installation and use of the device. The information contained in this publication has been carefully prepared and checked.
  • Page 16: Safety Instructions

    2. - SAFETY INSTRUCTIONS Caution! This product is not suitable for household illumination. Please read this manual before installing and applying power to the equipment, follow the safety precautions listed below and observe all warnings in this manual and printed on. Please contact a PROEL distributor for assistance with any questions about how to activate the equipment safely.
  • Page 17 IP65 PROTECTION RATING The device is protected against the dust penetration (first digit 6) and against jets of water (second digit 5). Suitable for outdoor use. PROTECTION AGAIN ELECTRIC SHOCK The device must be connected to a power supply system with efficient earthing. Moreover, it is recommended to protect power supply lines of the product from indirect contact and / or shorting to earth by using appropriately sized anti electrical shock switch.
  • Page 18: Opening And Control

    Verify that the box contains the following items: N° 1 SG SOLPARC60Z N° 1 Power cord N° 1 Anti glare circle N°...
  • Page 19: Installation And Switch On

    4. - INSTALLATION AND SWITCH ON 4.1 - PRODUCT INSTALLATION - Do not shake the device. Avoid the use of too much force during installation or unit fixing. - The unit can be installed on the floor resting on the rubber feet, on the wall, ceiling or on a truss.
  • Page 20 4.3 - CONNECTION TO THE DMX CHAIN Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5). Do not use microphone cable or other cable with different characteristics than those specified.
  • Page 21: Setup

    50 - 255 BLUE WhiteBal 50 - 255 WHITE TimeInfo Current (h) Info TimeInfo TotalTim (h) Working time information TimeInfo TimeInfo LastClea TimeInfo TimerPIN Info TempInfo Info TempInfo XXX °C Info SAGITTER Sol_P60 ModelInf Info 1U V103 Software version Software 2U V103...
  • Page 22 Info None/ZOOM Zoom errore visualization ErrorInf Zoom reset Rset.M ZOOM ZoomRset Zoom calibration (password: 050) Calibrat 000-255 Slave Slave Slave mode ManCtrl 000 - 255 Zoom manual adjustment ZOOM ManCtrl 000 - 255 Strobe manual adjustment Strobe ManCtrl 000 - 255 Red manual adjustment Manual ManCtrl...
  • Page 23 Table 1: Built-in programs 1. STATIC R/G/B/RG/GB/RB/RGB/BLAC STR: 000-255 2. CHANG6 SP01-99 STR: 000-255 3. CHANG30 SP01-99 STR: 000-255 4. FADE SP01-99 STR: 000-255 Table 2: Macro list Green Blue White 001 - 004 005 - 008 009 - 012 013 - 016 017 - 020 021 - 024...
  • Page 24 137 - 140 141 - 144 145 - 148 149 - 152 153 - 156 157 - 160 161 - 164 165 - 168 169 - 172 173 - 176 177 - 180 181 - 184 185 - 188 189 - 192 193 - 196 197 - 200 201 - 204...
  • Page 25 5.3 - DMX MODE Value Function 000-255 000-255 000-255 000-255 000-255 Dimmer 000 - 015 Led’s On 016 - 031 Led’s Off 032 - 063 Led’s On 064 - 095 Strobe effect slow to fast 096 - 127 Led’s On 128 - 159 Pulse-effect in sequences 160 - 191...
  • Page 26: Maintenance

    6. - MAINTENANCE To ensure optimal performance, the unit must be frequently cleaned. Unplug the device from the mains and let it cool for at least 35 minutes to avoid the risk of burns. Use a vacuum cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited. The lenses, like any other damaged part, must be replaced with original spare parts.