7. Technical characteristics
1. NOMINAL POWER SUPPLY
2. MAX. CURRENT CONSUMPTION
(WITHOUT LIGHTS)
3. MODULES' CONSUMPTION
4. MAXIMAL / POSSIBLE
CONFIGURATION
5. AVAILABLE INPUT MODULES
6. LIGHTS' POWER RANGE
7. INPUT MODULES POWER
RANGE
8. LIGHTS' FUSES
9. LIGHTS' TURN ON / OFF IN CASE
OF EMERGENCY
10. ALARM / SIGNALIZATION OUTPUT
11. LIGHTS' CIRCUIT FAILURE ALARM
DELAY
12. EXTERNAL ALARM ACCEPT
INPUT
13. COMMUNICATIOS BETWEEN
MODULES
14. LIGHTS' CONFIGURATION AND
CONDITION
230 V ac, 115 V ac or 24 V dc , depending on version, main and
emergency power supply with automaitc change-over, power supply
failure indication
230 V ac version - 0.135 A max
115 V ac version - 0.27 A max
24 V dc version - 2 A max
Main unit ITNSL-01TP
Input module ITNL-10-D-230 : 19 V dc, 0.16 A max
Input module ITNL-5-D-230
Input module ITNL-10-S-230 : 19 V dc, 0.19 A max
Input module ITNL-13-S-230 : 19 V dc, 0.2 A max
Input module ITNL-10-D-24
Input module ITNL-5-D-24
Input module ITNL-10-S-24
Input module ITNL-13-S-24
Up to 5 input modules (in total) can be installed
Up to 3 pcs. of ITNL-10-D or ITNL-5-D (double lights)
Up to 5 pcs. of ITNL-10-S or ITNL-13-S (single lights)
ITNL-10-D and ITNL-10-S can be combined in the same system
Maximum number of lights: 80 (in configuration 30 double lights
and 20 single lights)
ITNL-10-D-XXX for 10 double lights*
ITNL-5-D-XXX for 5 double lights*
ITNL-10-S-XXX for 10 single lights**
ITNL-13-S-XXX for 13 single lights**
XXX -230 for 230/115 V AC light power supply
- 24 for 24 V DC light power supply
* can be used for single lights
** can be used for double lights, however each light uses 2 inputs
4-100 W (230 V ac)
4-65 W (115 V ac)
4-40 W (24 V dc)
Flashing lights are allowed
800 W (230 V ac)
430 W (24 V dc)
5x20mm, each pole, mounted on input modules
Manual activation of lights directly on input modules, power
supply
SYSTEM OPERATING voltage-free C.O. contacts 250 V ac/1A,
for indicating that system is functioning correctly
COMMON ALARM voltage-free C.O. contacts 250 V ac/1A, for
broken light circuit alarm and power/system failure alarm
NMEA 0183 TRANSMITTER - $NLALR sentences for normal
state, alarm state, main and emergency supply alarms
2-6 s, automatic change-over to spare light (if exists)
N.O. Voltage-free contact, quits buzzer only
NMEA 0183 receiver - $--ACK sentence for external audio alarm
acceptance, quits buzzer only
RS485, ITNL addresses configured via dip switch
Presented on 7" TFT touch display
39
: 19 V dc, 0.54 A max
: 19 V dc, 0.1 A max
: 24 V dc, 0.27 A max
: 24 V dc, 0.14 A max
: 24 V dc, 0.27 A max
: 24 V dc, 0.3 A max
Rev.: 4, Print date: 2021-05-05
NL95