Manual Operation Mode - Glamox NL95 User Manual

Touch screen navigational light controller
Table of Contents

Advertisement

5.2 Manual operation mode

Manual operation mode enables user to manualy switch on/off lights in case of emergency. Lights can be switch
on/off by slide switches on the Input modules. In case of manual operation power supply will be directly forwarded to
lights, bypassing all electronics. Fuses will remain in circuit. In case of manual operation, it is recommend that Input
module is disconnected from communication line (RJ45 cable - connectors). Please check troubleshooting section.
POWER ON
F1
FAILURE
5
1
Switches for manual operation are located on Input modules
2
Power supply is directly forwarded to Input modules
3
Fuses will remain in circuit (Lights remain individually fused)
4
Lights are not controlled and their operation needs to be visually checked
5
Navigation lights controller can not control manual operated light
IMPORTANT!!!
There is 230 V ac on PCB. For manual operation use insulated screwdriver.
1
Slide switches for manual light
operation
Slide switches in one direction for
manual operation of light.
ITNL-10-D module
MAIN light switched ON
SPARE light switched ON
CON1
CON2
CON3
CON1
CON2
CON3
MAIN UNIT
INPUT
ITNSL-01TP
MODULES
2
POWER SUPPLY
35
C.O. VOLTAGE-FREE OUTPUT CONTACT
SYS
AL1
AL2
AL3
RX
TX
B A B A
-
1
2 3 4
5 6 7 8 9 10
12 13 14 15 16
17
18 19 20
21
NMEA 0183
COMMON ALARM OUTPUT
RECIEVER
SYSTEM OPERATING
AUDIO ALARM ACCEPT INPUT
NMEA 0183
TRANSMITTER
3
MANUAL
OPERATION
1 1
ITNL-10-S module
Light switched ON
Light switched OFF
NL95
CONTROL
4
1
1
Rev.: 4, Print date: 2021-05-05
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents