Service; Faults Identification And Repair; Figure 7 Cleaning The Condenser - Igloo JSCRP Instruction Manual

Pastry display cases
Table of Contents

Advertisement

REFRIGERATION LTD

Figure 7 Cleaning the condenser

The seller shall not be held responsible for the any condenser damages in the case of
non-observance of condenser cleaning instructions.
Do not use mechanical agents to quicken the defrosting process!

6. SERVICE

6.1. Faults identification and repair

In case of any difficulties during actuation of the equipment or during its operation, please return to the chapters in
this manual, which explain the performed operation. This aims to ensure the equipment is properly operated. If you
still experience difficulties, the following might help you solve the problems.
The equipment is not working... – Make sure that:
• The equipment is connected to the power supply.
• The Voltage and frequency in the network are compliant with those recommended by the manufacturer,
115V/60Hz.
• The main switch is turned on.
• The Thermostat is turned on.
The equipment is operating, but the light is off... – Make sure that:
• Light switch is turned on.
• Lamp or starting switch of the equipment is not burnt.
Water leakage from under the device
• Check whether the unit is properly levelled.
• Empty the condensate container.
The equipment does not reach the proper temperature, the light is on... – Make sure that:
• The main switch is on.
• Temperature setting on the thermostat is properly set.
• Thermostat works properly.
• The condenser is clean, if necessary – clean the condenser.
• Ambient temperature does not exceed 25ºC.
Pastry Cases | www.igloorefrigeration.com
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

J2scrp

Table of Contents