Comelit VEDO System Manual
Hide thumbs Also See for VEDO:
Table of Contents

Advertisement

Quick Links

EN
SYSTEM
MANUAL
Vedo system 2.12.x
Passion.Technology.Design.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEDO and is the answer not in the manual?

Questions and answers

Summary of Contents for Comelit VEDO

  • Page 1 SYSTEM MANUAL Vedo system 2.12.x Passion.Technology.Design.
  • Page 2 Certifications • All the products comply with the requirements of the 2014/30/EU and 2014/35/ • This Comelit product has been designed and manufactured for use in the EU directives. This is proved by the CE mark on the products themselves.
  • Page 3: Table Of Contents

    3.8 OTHER DEVICES THAT CAN BE CONNECTED TO THE 485 BUS..........26 5.5.5 Input/output expansions (8I8O) ....................52 3.8.1 Vedo Touch (Art. VEDOTOUCH) / Mini Touch (Art. 20034607) with RFID key reader ..26 5.5.6 Power supply stations ......................52 3.8.2 Planux Manager with RFID key reader (Art. 20034801)............27 5.5.7 Isolators ..........................53...
  • Page 4: Introduction To The System

    38400 baud. capable of meeting the technical and performance requirements of modern security systems to the best effect. The Vedo system allows the creation of 1.1.2 Addressing the modules systems that require up to 200 individual standard zones with double or triple The modules are all connected to the same Bus, and are recognisable by their balance, which can be assigned to a maximum of 16 areas.
  • Page 5 • Control panel management vie Internet through Vedo App art. VEDOGSM3G) • Event alert via email and on Vedo App with alerts with proprietary protocol • GSM/GPRS channel support (with art. VEDOGSM) • Alert by email for alarms/malfunctions/sabotage/events with images •...
  • Page 6: Power Supply Unit Technical Specifications

    ATS CATEGORIES BASED ON CONFIGURATIONS The Vedo control panels equipped with transmission devices (integrated or optional extras) listed in the table below are SPTs (Supervised Premises Transceiver) which interface with the alarm system and transmit alarms via various networks. SPT CONFIGURATION...
  • Page 7: Power Supply Unit Technical Specifications

    Art. PSU15 / PSU50 conforms to standards EN50130-4:2011, EN 62368-1/A1:2018 Power supply unit versions PSU15 PSU50 Name of manufacturer / supplier Comelit Group S.p.A. Comelit Group S.p.A. Dimensions (L x H x D) 78 x 110 x 36 mm 98 x129 x40 mm...
  • Page 8: Identification Of Parts And Separation Of Circuits

    2. Identification of parts and separation of circuits 2.1 POSITIONING OF COMPONENTS AND FIXTURES (FOR ART. BOXPLASTIC) 1. Holes for fixing the housing 2. Clips for fixing the control panel board Art. PCBVEDO10 PCBVEDO34 - PCBVEDO68 - PCBVEDO200 - PCBPSU 3.
  • Page 9: Positioning Of Components And Fixtures (For Art. Boxmetal)

    2.3 POSITIONING OF COMPONENTS AND FIXTURES (FOR ART. BOXMETAL) 1. GSM antenna output 2. Supports fixing control panel board Art. PCBVEDO10 - PCBVEDO34 - PCBVEDO68 - PCBVEDO200 - PCBPSU 3. Holes for fixing the housing 4. Cable routing holes 5. Supports for fixing ( ) and holding expansion Art.
  • Page 10: Boxmetal)

    2.4 ROUTES FOR SEPARATING THE SELV CIRCUIT AND THE HIGH VOLTAGE CIRCUIT (FOR ART. BOXMETAL) 1. GSM antenna output 2. Expansion antenna connector Art. VEDOGSM / VEDOGSM3G VEDOGSM4G 3. PSU connector 4. Battery connector 5. VEDOIP expansion network connector 6. Balance resistor 7.
  • Page 11: Technical And Installation Specifications

    The control panel board is supplied with a built-in digital dialler, which allows the Features Value transmission of voice messages by means of an additional audio/voice control Name of manufacturer / supplier Comelit Group S.p.A. module. Dimensions (b x h x d) 280 x 260 x 80 mm It is equipped with 8 standard wired zones and one anti-tamper zone.
  • Page 12: Technical Specifications

    Fixtures for boards/expansions Features Value CAUTION! With PCBVEDO200 control panel board. If more than 20 peripherals are connected to the system via BUS: Name of manufacturer Comelit Group S.p.A. / supplier • keypads (VEDOKP, VEDOKP200, VEDOKPR, VEDOKPR200, VEDOLCD, VEDOLCDPROX) Dimensions (b x h x d) 140 x 127 x 28 mm •...
  • Page 13: Internal Expansions

    Operating temperature -10° / + 55° with warm dry air Name Function and Operating -10° / + 40°C with max + 93% RH (not Connection for alarm relay switching control panel pin humidity condensed) (RY1) Operating voltage 10 V to 15 V Normally closed connection for alarm relay (RY1).
  • Page 14: Messages And Voice Control Expansion Module (Art. Vedovoice)

    Generation and/or transmission voice messages: 10 sec times of alarm messages Features Value CONTACT ID: times according Name of manufacturer / Comelit Group S.p.A. Times for generating a reply to standard SIA DC-05-1999.09 supplier signal SIA: times according to Dimensions (b x h x d) 24 x 21 x 12 mm...
  • Page 15 >= 004 the time of initialisation. Name of Red LED lit steadily: during reset, during initial manufacturer / Comelit Group S.p.A. configuration of the module and when engaged by the supplier control panel to communicate via GSM/GPRS. Dimensions 70 x 48 x 29 mm 72 x 48 x 29 mm Flashing red LED: in all other conditions.
  • Page 16 Art. VEDOGSM (protocol < = 004) Name Function Green LED: module serial communication. Lights up briefly when the module communicates with the control panel. Red LED off: indicates that there is no signal (e.g. antenna or SIM card missing) Red LED lit: radio connection active. Four different levels of strength indicate the level of GSM signal received.
  • Page 17: Gsm Communication Expansion Module (Art. Vedogsm3G)

    (downwards if the control panel is already mounted on the wall). Name of manufacturer Comelit Group S.p.A. / supplier 2. Once you have overcome the resistance, turn it over on its hinges. 3. Insert the SIM card in the mobile part in such a way that you can...
  • Page 18: Gsm Communication Expansion Module (Art. Vedogsm4G)

    SIM fault: 20 sec management of the control panel by a voice dialler. The module also allows antenna disconnected: 45 sec connection from the Comelit app. Method for signalling faults Alert send failure: regular or on event to alarm system...
  • Page 19 Level of output signals Minimum level DTMF tones at input: 36mVeff - and/or sensitivity of input 28.8dbV 100mVpp signals Level DTMF tones at output: low freq 9 dBm / high freq 11 dBm Safety signals level ATS2-I0 no protection supplied of information ATS2-S0 no protection Fig.
  • Page 20: Tcp/Ip Ethernet Expansion Module (Art. Vedoip)

    Meaning of the LEDs of the RJ45 network connector • Programming and Monitoring of the control panel via Internet through Safe Manager • Control panel management vie Internet through Vedo App Name Function • Event alert via email and on App with alerts...
  • Page 21: General Information About Connecting Devices To The Bus

    Meaning of the LEDs on the IP module (Normal operating mode) Non-compliance with the above cable types and methods may cause communication errors or poor quality communication between modules and the Name Status Function control panel. There is also a risk that the conductors of the cables themselves flashing might not be shielded correctly.
  • Page 22: Normally Open (No)

    ALARM JAMMING TAMPER ALARM ALARM 3.6.2 Normally open (NO) NO: detects the closure of a normally open contact connected between 3.6.7 Double zone (double) an input terminal and the respective negative (-V). It is not capable of Detects and distinguishes the opening of two normally closed contacts, detecting a line sabotage state: in the event of a line short-circuit, it can usually relating to two different sensors, disposed in series with a line generate an error or alarm;...
  • Page 23: Control And Display Components

    RFID key reader art. VEDOKPR, VEDOKPR200. Features Value Name of manufacturer / supplier Comelit Group S.p.A. The LCD keypad allows an authorised user to enable and disable the Dimensions (b x h) 137 x 127 x 24 mm system, to check the system status and manage its general features, and to check the event log history.
  • Page 24: Lcd Keypad Art. Vedolcd And Keypad With Rfid Key Reader Art. Vedolcdprox

    Display contrast • Keypad and display backlighting level Note that the standard speed of the bus for VEDO control panels is 38400 baud. Caution: when you enter the local configuration menu, the keypad will be temporarily disconnected from the BUS.
  • Page 25 MEANING OF THE LEDs WITH THE READER IN STANDBY (no cycle in progress) TEST Status Function Scenario associated with the Red LED active Slow System not armed and alarm, tampering or flash fault event memory present Fast System armed and alarm, tampering or fault flash event memory present Scenario associated with the Blue LED active...
  • Page 26: Rfid Keys (Art. Sk9050X/A)

    7. CV8 Used in conjunction with the RFID key readers (on bus, on keypad, on Vedo Touch, on Minitouch or on Planux Manager), they make it possible to activate and deactivate the system without any need for electrical contact. The RS485 bus of the device must be connected exclusively to An RFID key can be associated to each user.
  • Page 27: Planux Manager With Rfid Key Reader (Art. 20034801)

    20034801) ADDRESSING THE DEVICE ON THE BUS Like any other device connected to the 485 bus, the Vedo Touch/Mini Planux Manager is a built-in system manager: as well as incorporating Touch must respond to a single address that can be configured from all the control features available on Mini Touch, it performs advanced, the display.
  • Page 28: Icona Manager Vip (Art. 20003310W)

    Icona Manager ViP is a built-in system manager with door entry Device Type A according to EN50131-3 monitor functions and the ability to display and check the status of the Environmental class I according to EN50131-1 SimpleHome home automation system and of the Vedo anti-intrusion system.
  • Page 29: Expansions On 485 Bus

    3.9.1 Plastic expansion housing DESCRIPTION OF TERMINAL BLOCK 1 Name Function negative of the secondary RS485 bus (terminal not fitted by product rev1.0) positive of the secondary RS485 bus (terminal not fitted by product rev1.0) negative of the alarm RS485 bus positive of the alarm RS485 bus board earth negative pole of the additional ringtone output...
  • Page 30 TYPE B according to standard Device Type 115200 EN50131-3 Environmental class II according to EN50131-1 Note that the standard speed of the bus for VEDO control panels is 38400 baud. * Observing any indications for configuration and installation TERMINAL BLOCK M1 CONFIGURATION JUMPERS...
  • Page 31: Two-Way Radio Expansion On Bus (Art. Rf10Vedo / Rf32Vedo)

    Separate management of intruder and sabotage alarms 115200 • Radio device power supply monitoring, including sirens • Monitoring Note that the standard speed of the bus for VEDO control panels is 38400 baud. TERMINAL BLOCK DESCRIPTION Name Function Power supply positive input...
  • Page 32 Operating temperature -10° / +40°C • the function of sending 4 frames captured by the camera in the Operating humidity max +85% RH (not condensed) alarm zone to system managers (Vedo Touch, Mini Touch, Icona Manager ViP) and the App;...
  • Page 33: Wireless Sensors And Accessories

    After configuring the system and the film recording function correctly: • the alert function will send 4 frames (captured in successive moments by the camera in the alarm zone) to system managers (Vedo Touch, Mini Touch, Icona Manager ViP) and to the App. V+SIR V+SIR •...
  • Page 34: Example Of Connection To Outputs Tc1 And Tc2

    • When the device is connected to a Vedo series control panel, it is V+SIR possible to monitor the status of the auxiliary power supplies and the power supply unit itself.
  • Page 35 SETTING THE SPEED OF THE BOARD ON THE BUS -10° / + 40°C with max + 93% Operating humidity Note that the standard speed of the bus for VEDO control panels is RH (not condensed) 38400 Baud. TYPE A according to standard...
  • Page 36: Bus Ator (Vedoiso)

    The section of the system that you want to isolate from the rest must be connected to the OUT port. V- V+ SETTING SPEED ON THE BUS Art.VEDOISO Note that the standard speed of the bus for VEDO control panels is 38400 Baud. BAUD DIP5 DIP6...
  • Page 37: Appendix: Mounting Instructions

    4. Appendix: Mounting instructions 4.1 OPENING THE HOUSING ART. BOXPLASTIC 4.2 PREPARING THE HOUSING ART. BOXPLASTIC If the control panel is already assembled, you will have to remove the electronics boards and the power supply unit from the housing, so as not to risk damaging them 4.3 FIXING THE HOUSING ART.
  • Page 38: Mounting The Control Panel Board Art. Pcbvedo10, Pcbvedo34, Pcbvedo68, Pcbvedo200, Pcbpsu In Housing Art. Boxplastic

    4.4 MOUNTING THE CONTROL PANEL BOARD 4.5 MOUNTING THE POWER SUPPLY UNIT PSU15 IN A ART. PCBVEDO10, PCBVEDO34, PCBVEDO68, HOUSING ART. BOXPLASTIC PCBVEDO200, PCBPSU IN HOUSING ART. BOXPLASTIC MOUNTING EXPANSION ART. VEDO8I8O RF10VEDO, RF32VEDO HOUSING ART. BOXPLASTIC CLACK!
  • Page 39: Opening The Housing Art. Boxmetal

    4.7 OPENING THE HOUSING ART. BOXMETAL open 4.8 FIXING THE HOUSING ART. BOXMETAL TO THE WALL The metal housing should be secured to the wall with the 5 FISCHER SX 6 S screws/wall plugs ART.570021 provided.
  • Page 40: Pcbvedo200 And Pcbpsu In Housing Art. Boxmetal

    4.9 MOUNTING THE CONTROL PANEL BOARD ART. 4.10 MOUNTING THE EXPANSION ART. VEDO8I8O IN PCBVEDO10 PCBVEDO34 PCBVEDO68 HOUSING ART. BOXMETAL PCBVEDO200 AND PCBPSU IN HOUSING ART. BOXMETAL 4.11 MOUNTING THE POWER SUPPLY UNIT PSU15 - PSU50 IN A HOUSING ART. BOXMETAL CLACK! LOCKING (OPTIONAL)
  • Page 41: Mounting The Module Art. Vedocctv In Metal Housing

    4.12 MOUNTING THE MODULE ART. VEDOCCTV IN METAL HOUSING ART. BOXMETAL 4.13 MOUNTING THE MODULE ART. 30076003 / 30076004 IN METAL HOUSING ART. BOXMETAL only with art. 30076004...
  • Page 42 4.14 MOUNTING THE KEYPAD ART. VEDOKP, VEDOKP200, VEDOKPR, VEDOKPR200 IN BOX 503 CLACK OPENING 4.15 SURFACE-MOUNTING THE KEYPAD ART. VEDOKP, VEDOKP200, VEDOKPR, VEDOKPR200 CLACK OPENING...
  • Page 43: Mounting The Vedo Touch / Mini Touch (Art. 20034607) In Box 503

    4.16 MOUNTING THE VEDO TOUCH (ART. VEDOTOUCH) / MINI TOUCH (ART. 20034607) IN BOX 503 OPENING...
  • Page 44: Mounting Planux Manager (Art. 20034801) With Flush-Mounted Box Art. 6117

    4.17 MOUNTING PLANUX MANAGER (ART. 20034801) WITH FLUSH-MOUNTED BOX ART. 6117 14,5 cm ALTO HAUT OBEN DISASSEMBLY...
  • Page 45: Mounting Planux Manager (Art. 20034801) With Wall Bracket Art. 6120

    4.18 MOUNTING PLANUX MANAGER (ART. 20034801) WITH WALL BRACKET ART. 6120 14,5 cm DISASSEMBLY...
  • Page 46: Wall-Mounting Icona Manager Vip / Mounting In 503 Series Box / Round Box

    4.19 WALL-MOUNTING ICONA MANAGER VIP (ART. 6620) / MOUNTING IN 503 SERIES BOX / ROUND BOX with Art.6620* 14,2 cm with Art.6620* with Art.6620* L min = 6,5 cm L max = 7 cm Art. 20003310W * Art. 6620 (optional) CLACK ! DISASSEMBLY...
  • Page 47: Mounting Icona Vip Manager In A Flush-Mounted Box Art. 6117

    4.20 MOUNTING ICONA VIP MANAGER IN A FLUSH-MOUNTED BOX ART. 6117 14,2 cm = 6 cm = 10 cm CLACK ! Art. 20003310W DISASSEMBLY...
  • Page 48: Rf32Vedo / Vedo8I8O

    4.21 PREPARING THE PLASTIC HOUSING FOR MOUNTING THE EXPANSION ART. RF10VEDO / RF32VEDO / VEDO8I8O VEDO8I8O VEDORF 4.22 WALL-MOUNTING THE PLASTIC HOUSING FOR EXPANSION ART. RF10VEDO / RF32VEDO / VEDO8I8O OPENING...
  • Page 49: Appendix: Notes On Installation And Programming

    5. Appendix: notes on installation 5.3.3 Keypad navigation mode It is possible to configure the system and enter or modify data using one and programming of the system keypads.  Use the keys to move about within the menu and the key to pass to the next level or to confirm entry of a new data item.
  • Page 50: Total Arming Of The Alarm System

    14. Once you have finished making changes from the keypad, remember 2. Once the code has been recognised, press the Prog key until the to transfer them to the PC using the Comelit alarm control panels message “DONE” appears on the screen.
  • Page 51: Acquiring A Siren Code From The Keypad

    5.3.20 Setting the control panel to Service Status control is to be associated and press Confirm. This function allows the installer to work on the Vedo System with Once you have finished making changes from the keypad, remember complete peace of mind, with the siren, PSTN part, GSM part and to transfer them to the PC using the Comelit alarm control panels email all "silenced".
  • Page 52: Configurations Necessary To Guarantee Grade 2 Certification According To

    5.5.1 Keypads EXAMPLE 1: "ENABLE BUZZER" ON KEYPAD 1 Vedo10 x: from 1 to 2 / Vedo34 x: from 1 to 8 / Vedo68 x: from 1 to 8 / Vedo200 x: from 1  Traditional navigation with keys to 16 Configurations necessary to Indices Parameters...
  • Page 53: Isolators

    RADIO OUTPUT CONFIGURATION Configurations necessary to Indices Parameters guarantee Grade 2 certification Configurations necessary 1.1.1.8.x.10 Send email Selected Indices Parameters to guarantee Grade 2 Send digital certification 1.1.1.8.x.11 Selected communications 1.1.1.11.x.28.1.1 Timer in And * No timer 1.1.1.8.x.13 Tamper enabled Selected 1.1.1.11.x.28.1.2 Timer in Or...
  • Page 54: Areas

    code and can create and eliminate another user, whereas he is unable to Configurations necessary to Indices Parameters modify any user code other than his own. guarantee Grade 2 certification 1.1.1.14.x.15.y.4 Alarm cycles Unlimited Can be self-disabled CODE TYPE 1.1.1.14.x.15.y.22 Deselected (alarm only) x: from 1 to 9...
  • Page 55: Phone Book / Email

    Configurations necessary to Configurations necessary to Indices Parameters Indices Parameters guarantee Grade 2 certification guarantee Grade 2 certification 1.1.1.28.1.21 Alert Priority Setup SMS and MMS follow 1.1.1.32.x.4 Areas At least one selected 1.1.1.28.1.22 PSTN switchboard prefix * Empty * The PSTN line must be connected before the switchboard. DETAILED EVENTS FLAGS For DP1 and DP3 the flags "Use second channel as backup”...
  • Page 56: Service Voice Messages

    1.1.1.32.x.6.y.47 Radio control fault * - activation: Selected 1.1.1.32.x.6.y.94 Auxiliary power supply * - activation: Selected * - restore: Selected fuse fault * - restore: Selected 1.1.1.32.x.6.y.48 Power supply unit fuse fault * - activation: Selected 1.1.1.32.x.6.y.95 Bus power supply fuse fault * - activation: Selected * - restore: Selected * - restore: Selected 1.1.1.32.x.6.y.49...
  • Page 57: Timer Model

    Configurations necessary to 1.1.1.44.x.29 Safetouch tamper Selected Indices Parameters guarantee Grade 2 certification 1.1.1.44.x.30 Touch Tamper Selected 1.1.1.44.x.31 Bus power supply station or Selected * Timer 4 completed and linked with the two regular general events isolator tamper 1.1.1.44.x.32 Bus radio concentrator Selected 5.5.26 Timer Model tamper...
  • Page 58: Configurations Necessary To Guarantee Incert Certification

    5.6.1 Code type 1.1.1.44.x.126 Change date and time Selected 1.1.1.44.x.127 Change site data Selected Configurations necessary to Indices Parameters 1.1.1.44.x.130 Telephone call failed Only set selected guarantee INCERT certification 1.1.1.44.x.131 Outgoing phone Selected Selected 1.1.1.22.x.45 Reset alarms L3 communication Deselected for manufacturer 1.1.1.44.x.132 Digital dialler periodic test Selected...
  • Page 59: Power Supply Connections

    ______________________________________________________________________ 5.9 DATA NETWORK CONNECTION CABLE To connect the IP module from the Vedo control panel to a data network, you need to go through a hub or a network switch. The control panel will be connected by means of a network cable in straight configuration.
  • Page 60 C E R T I F I E D M A N A G E M E N T S Y S T E M S w w w . c o m e l i t g r o u p . c o m Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy...

This manual is also suitable for:

Vedo10Vedo34Vedo34mVedo68Vedo68mVedo200 ... Show all

Table of Contents