Comelit VEDO10 System Manual
Hide thumbs Also See for VEDO10:
Table of Contents

Advertisement

Quick Links

S Y S T E M M A N U A L
Scansionare il seguente codice QR per leggere questo manuale in italiano
Encadrer le code QR ci-après pour lire ce manuel en français
Scan de volgende QR-code voor deze handleiding in het Nederlands
Escanear el siguiente código QR para leer este manual en español
Warning
Intended use
This Comelit product has been designed and manufactured for use in the
creation of security and automation systems in residential, commercial,
industrial and public buildings.
Installation
All activities connected to the installation of Comelit products must be
carried out by qualified technical personnel, with careful observation of
the indications provided in the Manuals / Instruction sheets supplied with
those products. The product must be installed to the highest standards.
Wires
Disconnect the power supply before carrying out any operations on the
wiring. Use wires with a cross-section suited to the distances involved,
observing the instructions provided in the system manual. We advise
against running the system wires through the same duct as power cables
(230V or higher).
Safe usage
To ensure Comelit products are used safely:
• carefully observe the indications provided in the Manuals / Instruction
sheets
• make sure the system created using Comelit products has not been
tampered with / damaged.
Maintenance
Comelit products do not require maintenance aside from routine cleaning,
which should be carried out in accordance with the indications provided in
the Manuals / Instruction sheets.
Any repairs must be carried out:
• for the products themselves, exclusively by Comelit Group S.p.A.,
• for the systems, by qualified technical personnel.
Do not use alcohol or aggressive products for cleaning purposes.
Disclaimer
Comelit Group S.p.A. does not assume any responsibility for:
• any purpose other than the intended use
• failure to observe the indications and warnings contained in this Manual
/ Instruction sheet.
Comelit Group S.p.A. reserves the right to change the information
provided in this Manual / Instruction Sheet at any time and without prior
notice.
Directives
The manufacturer, Comelit Group S.p.A.,  hereby declares that
this equipment conforms to the applicable directives. The full EU
conformity declaration is available on the product web page.
Vedo 2.15.x
VEDO10
VEDO34
VEDO34M
VEDO68
VEDO68M
VEDO200
VEDO200M
In accordance with art. 26 of Italian Legislative Decree dated
14th March 2014, no. 49 "Implementation of directive 2012/19/
EU on Waste Electrical and Electronic Equipment (WEEE)". the
"crossed-out wheelie bin" symbol indicates that at the end of its
useful life, this product must be separated from other waste
before collection for disposal. The user should therefore take the exhausted
appliance to suitable local collection centres for waste electrical and
electronic products. As an alternative to handling this process yourself,
you can take the appliance to your local equipment dealer when purchasing
a new equivalent product. Electronics dealership businesses covering an
area of 400 m² are also obliged to accept waste electronic products
smaller than 25 cm for disposal, without any obligation to purchase.
Suitable separated waste collection for the subsequent reuse of the
appliance sent for recycling, processing and environmentally conscious
disposal helps to avoid potential negative effects on the environment and
human health, and encourages the reuse and recycling of the materials
used in the construction of the appliance.
Key to symbols
ISO 7000-0434
Caution! Refer to the documentation
ISO 3864
Caution! Risk of electric shocks
ISO 7000-1641
Read the operating instructions
IEC 60417-5017
Earth connection 
IEC 60417-5134
Devices sensitive to static electricity
IEC 60417-5031
Device powered with direct current
(2002-10)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEDO10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Comelit VEDO10

  • Page 1 Intended use useful life, this product must be separated from other waste This Comelit product has been designed and manufactured for use in the before collection for disposal. The user should therefore take the exhausted creation of security and automation systems in residential, commercial, appliance to suitable local collection centres for waste electrical and industrial and public buildings.
  • Page 2: Table Of Contents

    Table of contents Introduction to the system VEDOKP, VEDOKP200, VEDOKPR, VEDOKPR200 Mounting in box 503 DESCRIPTION OF SYSTEM COMPONENTS Surface mounting Communication standard VEDO5TPR, VEDO5TPRW Module addresses Preparing the plastic housing GENERAL INFORMATION Mounting in box 503 Main system specifications Mounting in a round box Power supply unit technical specifications RF10VEDO, RF32VEDO, VEDO8I8O...
  • Page 3: Introduction To The System

    Each input event can be associated with multiple outputs, thus potentially involving all the outputs configured at the installation stage. The flexibility of this arrangement makes it possible to adapt the control panel to the most wide-ranging requirements. MAIN SYSTEM SPECIFICATIONS INPUTS / OUTPUTS / BALANCING VEDO10 VEDO34 VEDO34M VEDO68...
  • Page 4 USER CODES / KEYS / REMOTE CONTROLS VEDO10 VEDO34 VEDO34M VEDO68 VEDO68M VEDO200 VEDO200M User code Installer code Manufacturer Code Remote controls Keys COMPATIBLE DEVICES / NUMBER OF DEVICES SUPPORTED VEDO10 VEDO34 VEDO34M VEDO68 VEDO68M VEDO200 VEDO200M Plastic housing Metal housing...
  • Page 5 VARIOUS FUNCTIONS COMMON TO ALL CONTROL PANELS • Up to 10 simultaneous connections • Telephone access via sounder or dialler • Telephone line status check • Skip Answerer • Possibility of sharing the telephone line with another answering device • Integrated voice calls (Text To Speech) •...
  • Page 6: Power Supply Unit Technical Specifications

    POWER SUPPLY UNIT TECHNICAL SPECIFICATIONS Technical specifications complying with EN 50131-6, the new standard establishing the required performance levels of a power supply unit in alarm systems. VEDO10 VEDO34 VEDO34M VEDO68 VEDO68M VEDO200 VEDO200M 260 x 280 260 x 280...
  • Page 7 MAXIMUM CURRENT AVAILABLE FOR EXTERNAL DEVICES, ON THE BASIS OF THE CONTROL PANEL CONFIGURATION POSSIBLE CONFIGURATIONS BATTERY POWER SUPPLY UNIT MAXIMUM CURRENT VEDO10 VEDO34 VEDO34M VEDO68 VEDO68M VEDO200 VEDO200M 30076004 PSU50 1500 mA for EN 50131-6 12 V and 750 mA for T031 √...
  • Page 8: Identification Of Parts And Separation Of Circuits

    Identification of parts and separation of circuits BOXSTANDARD POSITIONING COMPONENTS AND FIXINGS 1. Holes for securing the housing to the wall Mounting instructions on page 34 Optional Note: the housing should be secured to the wall using the screws and wall anchors provided. 2.
  • Page 9: Boxmetal

    BOXMETAL POSITIONING COMPONENTS AND FIXINGS 1. GSM antenna output 2. Supports for fixing control panel board PCBVEDO10 / PCBVEDO34 / PCBVEDO68 / PCBVEDO200 / PCBPSU 3. Holes for securing the housing to the wall Note: the housing should be secured to the wall using the screws and wall anchors provided.
  • Page 10: Routes For Separating The Low-Voltage Circuit (Selv) And High-Voltage Circuit

    ROUTES FOR SEPARATING THE LOW-VOLTAGE CIRCUIT (SELV) AND HIGH-VOLTAGE CIRCUIT 1. GSM antenna output 2. Expansion antenna connector VEDOGSM / VEDOGSM3G / VEDOGSM4G 3. PSU connector 4. Battery connector 5. VEDOIP expansion network connector 6. Balance resistor 7. Tamper connectors 8.
  • Page 11: Technical And Installation Specifications

    PCBVEDO10, PCBVEDO34, PCBVEDO68, TECHNICAL SPECIFICATIONS PCBVEDO200 Name of manufacturer / supplier Comelit Group S.p.A. Dimensions (w x h x d) 280 x 260 x 80 mm The control panel board is available in 4 versions with different features; 722 g (housing + micro switch +...
  • Page 12 COMUNICAZIONE IP V- 24H Name of manufacturer Holes for fixing the control panel board to the metal housing Art. Comelit Group S.p.A. / supplier BOXMETAL Dimensions (w x h x d) 140 x 127 x 28 mm Fixtures for boards/expansions...
  • Page 13: Internal Expansions

    CONFIGURATION JUMPERS Programmable input zone 2. JP1 If activated, enables 485 bus terminal resistor Inputs common / Power supply negative JP2 Reserved Programmable input zone 3. JP3 Reset (closing it and then opening it restarts the program) Programmable input zone 4. JP4 TC2 polarity: Open Collector (OC) or Positive Command on TC (TC) Programmable input zone 5.
  • Page 14: Vedovoice: Messages And Voice Control Expansion Module

    • Event transmission in Contact-ID and SIA (Level 1) format via GSM and over TCP-IP (SIA-DC-09 protocol support) Name of manufacturer / supplier Comelit Group S.p.A. • Event transmission by email with images Dimensions (w x h x d) 24 x 21 x 12 mm •...
  • Page 15 VEDOGSM VEDOGSM DL1 DL2 DL3 DL4 protocol < 004 protocol ≥ 004 Name of manufacturer / Comelit Group S.p.A. supplier Dimensions 70 x 48 x 29 mm 72 x 48 x 29 mm (w x h x d) (without antenna)
  • Page 16 MEANING OF THE LEDS < VEDOGSM protocol DL1 Red LED: GSM communication. Flashes when a transfer via the GSM or GPRS network is in progress, e.g. during receipt of an SMS or during registration with the network at the time of initialisation. DL2 red LED steadily lit: during reset, during initial configuration of the module and when engaged by the control panel to communicate via GSM/GPRS.
  • Page 17: Vedogsm4G: Gsm Communication Expansion Module

    Combined with the voice message board Art. VEDOVOICE, it allows remote management of the control panel by a voice dialler. The module also allows connection from the Comelit app. OK ! MODULE FUNCTIONS •...
  • Page 18 4. For the module to work, at least one of the two antennas must be voice messages: 10 sec Generation and/or connected and fastened to connector ANT1. email: 10 sec without image transmission times of 90 sec with image Connecting the second antenna improves performance in weak alarm messages MMS: 45 sec signal conditions.
  • Page 19: Vedoip: Tcp/Ip Ethernet Expansion Module

    Name of manufacturer / messages or transmit digital protocols via TCP-IP Comelit Group S.p.A. supplier It is not essential to unlock it, because the control panel is capable of Dimensions (w x h x d) 75 x 31 x 33 mm managing the PIN to unlock the SIM card.
  • Page 20: Vedowifi: Wi-Fi Communication Board

    Safe Manager. • VEDO control panel connectivity for all cloud-based operations. • Alarm/fault/sabotage event notification via e-mail/Comelit App. MEANING OF THE LEDS ON THE IP MODULE (PROGRAM UPDATING STAGE) D1+D2 steadily lit...
  • Page 21: General Information About Connecting Devices To The Bus

    POSITION WITH ITEM BOXMETAL VEDOWIFI RANGE In order to ensure stability when using the alarm control panel via Wi-Fi √ Place the antenna externally connection, we recommend checking in the Safe Manager that the Wi- Fi signal is strong enough. The recommended minimum value for the √...
  • Page 22: Wiring The Inputs

    KEYPADS CONNECTED IN SERIES SINGLE BALANCE For lengths up to 200 m, use the cable with cross-section 2x0.5 mm+2x0.22 Detects the opening of a normally closed contact disposed in series with a balanced line (on 1.8K) connected between an input terminal and the respective negative (-V).
  • Page 23: Control And Display Components

    VEDOKPR200 keypads have an RFID reader that is compatible with an alarm/electrical fault status and a line sabotage status, both in the Comelit RFID keys. event of cutting and short-circuit. The alarms are correctly recognised and These versions enable users, according to their authorisations, to arm assigned to the sensor from which they originate.
  • Page 24: Vedo5Tpr / Vedo5Tprw: Keypad With 5-Inch Touchscreen Display And Rfid Key Reader

    TECHNICAL SPECIFICATIONS Name of manufacturer / Comelit Group S.p.A. supplier Dimensions (b x h) 137 x 127 x 24 mm Weight 250 g art. VEDOKP, VEDOKP200 260 g art. VEDOKPR, VEDOKPR200 Consumption (min./max.) 30 mA with LEDs off, 80 mA during alarm signalling...
  • Page 25: Vedolcd: Lcd Keypad

    Type in the identification number of the device on the bus 7. uSD card The RS-485 bus for the device should only be connected to the alarm bus for the COMELIT VEDO control panel. TECHNICAL SPECIFICATIONS Name of manufacturer / Comelit Group S.p.A.
  • Page 26 DIP5 • Physical addressing of device by means of DIP switches. TECHNICAL SPECIFICATIONS Name of manufacturer / Comelit Group S.p.A. supplier Dimensions (w x h x d) 55 x 48 x 19 mm Weight 28 g 10 mA in Idle status Consumption (min./max.)
  • Page 27: Sk9050X/A: Rfid Keys

    Expansions on 485 bus MEANING OF THE LEDS WHEN THE CYCLE IS IN PROGRESS The expansion devices on bus VEDO8I8O and RF10VEDO / RF32VEDO are Request execution of action associated with supplied complete with plastic housing which complies with standard EN 50131;...
  • Page 28 Holes for fixing the VEDO8I8O board to the metal housing art. BOXMETAL TECHNICAL SPECIFICATIONS Features Value Name of manufacturer / Comelit Group S.p.A. supplier Dimensions (w x h x d) 126 x 80 x 32 mm (in the housing) 143 g with housing and screws for fixing to the...
  • Page 29: Rf10Vedo / Rf32Vedo: Bidirectional Radio Expansion On Bus

    TECHNICAL SPECIFICATIONS V+ AUX Power supply positive output Name of manufacturer / Comelit Group S.p.A. supplier Power supply negative - output reference Dimensions (w x h x d) 126 x 80 x 32 mm (in the housing) Input 1 / Output 1...
  • Page 30: Wireless Sensors And Accessories

    Wireless sensors and accessories CONNECTING A NON-SELF-POWERED INDOOR SOUNDER For further information on the correct positioning and mounting of wireless It is sometimes necessary to connect an additional, non-self-powered, sensors and sounders, refer to the respective instruction sheets enclosed indoor sounder as backup for the outdoor sounder. Using two-wire with the devices in question: connection for the outdoor self-powered sounder simplifies the wiring, as •...
  • Page 31: Example Of Connection To Outputs Tc1 And Tc2

    TECHNICAL SPECIFICATIONS For the connection of LEDs or small relays, refer to the diagram below. Name of manufacturer / supplier Comelit Group S.p.A. RELÈ ESTERNO SU TC2 MODO OC EXTERNAL RELAY ON TC2 OC MODE (JP4 SU OC)
  • Page 32: Vedoiso: Bus Isolator

    TERMINAL BLOCK M1-M2-M3-M4-M5-M6 LED MEANINGS Earth Earth connection terminal DL1 Flashing slowly: no data transfer over bus at the speed set using the DIP switch. Flashing quickly: data transfer over bus in progress. bus IN DL2 Off: the peripheral is communicating correctly. V+ 485 communication BUS power supply input positive Very slow flashing: (approx.
  • Page 33 115200 TECHNICAL SPECIFICATIONS The standard speed of the bus for Vedo control panels is 38400 baud. Name of manufacturer / Comelit Group S.p.A. supplier Dimensions (w x h x d) 56 x 53 x 19 mm CONFIGURATION JUMPERS Weight (without box) 26 g + 4 g fixing screws To access DIP switch S1 and jumpers JP1 and JP2, you must Consumption (min./max.) 40 mA...
  • Page 34: Mounting Instructions

    Mounting instructions BOXSTANDARD OPENING THE HOUSING STOP STOP PREPARATION If the control panel is already assembled, you will have to remove the PCBs and the power supply unit from the housing, so as not to risk damaging them.
  • Page 35: Wall Mounting The Housing

    WALL MOUNTING THE HOUSING The housing should be secured to the wall using the screws and wall anchors provided. FITTING CONTROL PANEL BOARD PCBVEDO10, FITTING POWER SUPPLY UNIT PSU15 PCBVEDO34, PCBVEDO68, PCBVEDO200, PCBPSU FITTING EXPANSION VEDO8I8O AND RF10VEDO, RF32VEDO...
  • Page 36: Boxmetal

    BOXMETAL OPENING THE HOUSING open open WALL MOUNTING THE HOUSING The housing should be secured to the wall using the screws and wall anchors provided.
  • Page 37: And Pcbpsu

    FITTING CONTROL PANEL BOARD PCBVEDO10 / FITTING EXPANSION DEVICE VEDO8I8O PCBVEDO34 / PCBVEDO68 / PCBVEDO200 AND PCBPSU FITTING POWER SUPPLY UNIT PSU15, PSU50 CLACK! LOCKING (OPTIONAL) FITTING BATTERY 30076003 / 30076004 # only with art. 30076004...
  • Page 38: Vedokp, Vedokp200, Vedokpr, Vedokpr200

    VEDOKP, VEDOKP200, VEDOKPR, VEDOKPR200 MOUNTING IN BOX 503 CLACK OPENING SURFACE MOUNTING CLACK OPENING...
  • Page 39: Vedo5Tpr, Vedo5Tprw

    VEDO5TPR, VEDO5TPRW PREPARING THE PLASTIC HOUSING MOUNTING IN BOX 503 MOUNTING IN A ROUND BOX...
  • Page 40: Rf10Vedo, Rf32Vedo, Vedo8I8O

    RF10VEDO, RF32VEDO, VEDO8I8O PREPARING THE PLASTIC HOUSING RF10VEDO RF32VEDO VEDO8I8O FIXING THE PLASTIC HOUSING TO THE WALL OPENING...
  • Page 41: Notes On Installation And Programming

    Notes on installation and DEFAULT CODES Master Installer Code: 001961 programming User 1 Code 111111 NAVIGATION MODE What to do before powering up the It is possible to configure the system and enter or modify data using one of the system keypads. system ...
  • Page 42: Full Arming Of The Alarm System

    14. Once you have finished making changes from the keypad, indicating that you can now modify the system options. remember to transfer them to the PC using the Comelit alarm control panels configuration program. ACCESSING PROGRAMMING MODE AS AN INSTALLER...
  • Page 43: Acquiring A Radio Control Code From The Keypad

    Once you have finished making changes from the keypad, remember 11a. If acquisition is successful, the display will show the serial number of to transfer them to the PC using the Comelit alarm control panels the sounder. configuration program.
  • Page 44: Exiting Service Status

    Keypads ..) ..KEYPADS LEVEL 3 Vedo10 x: from 1 to 2 / Vedo34 x: from 1 to 8 / Vedo68 x: from 1 to 8 / 10 × Keypad 1 Keypad 1 Vedo200 x: from 1 to 16 Description .16)
  • Page 45: Touch

    RADIO EXPANSION 1.1.1.1.x.45 Status LEDMode Deselected Vedo10 x: from 1 to 1 / Vedo34 x: from 1 to 2 / Vedo68 x: from 1 to 3 / Vedo200 x: from 1 to 8 TOUCH Configurations necessary to x: from 1 to 8...
  • Page 46: Remotes

    Vedo10 x: from 1 to 11 / Vedo34 x: from 1 to 64 / Vedo68 x: from 1 to 96 Vedo10 x: from 1 to 2 / Vedo34 x: from 1 to 8 / Vedo68 x: from 1 to 8 /...
  • Page 47: Installers

    Telephone 1.1.1.29.x.4 Line active * At least one selected Vedo10 x: from 1 to 3 / Vedo34 x: from 1 to 6 / Vedo68 x: from 1 to 6 / 1.1.1.29.x.7 Email receipt * At least one selected Vedo200 x: from 1 to 6...
  • Page 48: Detailed Events

    DETAILED EVENTS 1.1.1.32.x.6.y.45 Zone Fault * - activation: Selected * - restore: Selected x: from 1 to 8 y: from 1 to 8 1.1.1.32.x.6.y.46 Sounder fuse fault * - activation: Selected * - restore: Selected Configurations necessary to Indices Parameters 1.1.1.32.x.6.y.47 Radio control fault * - activation: Selected...
  • Page 49: Service Voice Messages

    1.1.1.44.x.12 Fire Alarm Selected 1.1.1.44.x.13 Panic Alarm Selected Vedo10 x: from 1 to 4 / Vedo34 x: from 1 to 8 / Vedo68 x: from 1 to 8 / 1.1.1.44.x.14 Robbery Alarm Selected Vedo200 x: from 1 to 32 1.1.1.44.x.15...
  • Page 50: Configurations Necessary To Guarantee Incert Certification

    1.1.1.44.x.20 Radio device jamming Selected 1.1.1.44.x.135 Lock keypad Selected 1.1.1.44.x.21 Tamper App Selected 1.1.1.44.x.140 Lock RFID Selected 1.1.1.44.x.26 Bus I/O expansions tamper Selected 1.1.1.44.x.143 Lock Web Selected 1.1.1.44.x.27 Bus keypad tamper Selected 1.1.1.44.x.144 Lock PC Selected 1.1.1.44.x.28 RFID tamper Selected 1.1.1.44.x.145 Lock SMS Selected...
  • Page 51: Official Symbol Conventions For Anti-Intrusion Systems

    Official symbol conventions for anti- POWER SUPPLY CONNECTIONS intrusion systems In the above circumstances, the resistance can be overlooked in the majority of cases. More care must be taken, however, if the cable has to carry power: in this case, the resistance could cause a significant drop for Magnetic contact detector the purposes of correct operation of the device you intend to power.
  • Page 52 C E RT I F I E D M A N A G E M E N T S Y ST E M S w w w . c o m e l i t g r o u p . c o m 1st edition 01/2024 Via Don Arrigoni, 5 - 24020 Rovetta (BG) - Italy code 2G40003217...

Table of Contents