Download Print this page

Milwaukee M18 POALC Original Instructions Manual page 18

Battery-lamp
Hide thumbs Also See for M18 POALC:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
TECHNICAL DATA
Lighting time with one fully charged battery (5.0 Ah)
Mode 3 High Level .............................................................
Mode 2 Med Level .............................................................
Mode 1 Low Level .............................................................
Luminus fl ux
High Level ..........................................................................
Med Level ..........................................................................
Low Level ..........................................................................
Colour rendering index (CRI).................................................
Colour temperature................................................................
AC-Mode
Voltage ...............................................................................
AC Input .............................................................................
Rated Power Input .............................................................
Charger rated power input .................................................
Charger output ...................................................................
Quick charge current .........................................................
DC-Mode
Rated Power Input .............................................................
Battery voltage ...................................................................
USB Output ..........................................................................
Weight without battery ..........................................................
Weight according EPTA-Procedure 01/2014 (2.0 Ah ...12.0 Ah) ......
Protection class ....................................................................
WARNING Read all safety warnings, instructions,
illustrations and specifi cations provided with this
power tool. Failure to follow all instructions listed below
may result in electric shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
BATTERY LAMP SAFETY INSTRUCTIONS
WARNING Do not direct the light beam at persons or
animals and do not stare into the light beam yourself (not
even from a distance). Staring into the light beam may
result in serious injury or vision loss.
CHARGER SAFETY INSTRUCTIONS
Do not store the battery pack together with metal objects
(short circuit risk).
Only the following battery packs can be charged with this
charger:
Battery Cat.
Cell Type
No.
M18B
Li-Ion
M18BX
Li-Ion
M18B2
Li-Ion
M18B4
Li-Ion
M18B5
Li-Ion
M18B6
Li-Ion
M18B9
Li-Ion
M18HB3
Li-Ion
M18HB4
Li-Ion
M18HB5.5
Li-Ion
M18HB8
Li-Ion
M18HB12
Li-Ion
Do not try to charge non-rechargeable batteries with this
charger.
No metal parts must be allowed to enter the battery section
of the charger (short circuit risk).
Never break open battery packs and chargers and store
only in dry rooms. Keep dry at all times.
Do not touch the tool with conducting objects.
Never charge a damaged battery pack. Replace by a new
one.
18
ENGLISH
470 426 - M18POALC.indd 18
470 426 - M18POALC.indd 18
BATTERY-LAMP
DC Volts
Capacity
Cell
No.
18 V
≤ 1.5 Ah
5
18 V
≤ 3.0 Ah
2 x 5
18 V
≤ 2.0 Ah
5
18 V
≤ 4.0 Ah
2 x 5
18 V
≤ 5.0 Ah
2 x 5
18 V
≤ 6.0 Ah
2 x 5
18 V
≤ 9.0 Ah
3 x 5
18 V
≤ 3.0 Ah
5
18 V
≤ 4.0 Ah
5
18 V
≤ 5.5 Ah
2 x 5
18 V
≤ 8.0 Ah
2 x 5
18 V
≤ 12.0 Ah
3 x 5
................................................................. 4 h
................................................................. 8 h
............................................................... 12 h
........................................................... 3000 lm
........................................................... 1500 lm
........................................................... 1000 lm
............................................................... 80
........................................................... 4000 K
...................................................... 100-240 V
................................................EU:220-240 V; UK:110V, 220-240V
............................................................. 130 W
............................................................... 80 W
............................................................... 18 V
.............................................................. 3,0 A
............................................................... 45 W
............................................................... 18 V
.............................................................. 5,0 V/2,1A
.............................................................. 5,5 kg
...................................................... 5,9...6,9 kg
................................................................ IP 54
Before use check machine, cable, and plug for any
damages or material fatigue. Repairs should only be
carried out by authorised Service Agents.
This appliance is not intended to
be used or cleaned by persons
with reduced physical, sensory or
mental capabilities, or lack of
experience or knowledge, unless
they have been given instructions
concerning the safe use of the
appliance by a person legally
responsible for their safety. They
should be supervised whilst using
the appliance. Children shall not
use, clean or play with this
appliance, which when not in use
should be secured out of their
reach.
ADDITIONAL SAFETY INSTRUCTIONS
Remove the battery pack before starting any work on the
appliance.
Do not dispose of used battery packs in the household
refuse or by burning them. Milwaukee Distributors off er to
retrieve old batteries to protect our environment.
Do not store the battery pack together with metal objects
(short circuit risk).
Use only compatible Milwaukee chargers from the same
battery platform for charging battery packs. Do not use
battery packs from other systems.
Battery acid may leak from damaged batteries under
extreme load or extreme temperatures. In case of contact
with battery acid wash it off immediately with soap and
M18 POALC
03.05.2021 14:53:41
03.05.2021 14:53:41

Advertisement

loading