Trane TCONT900AC43UA Installer's Manual page 13

Hide thumbs Also See for TCONT900AC43UA:
Table of Contents

Advertisement

Installer Setup
Selection
Furnace Filter 2
0501
Change Reminder
Humidifier Pad
0510
Replacement
Reminder
Adaptive Intelligent
0530
Recovery
Number of Periods
0540
Heat Temperature
0600
Range Stop
Cool Temperature
0610
Range Stop
Minimum
0620
Noncompressor On
Time
Table 4. Installer Setup Menu
Factory
Number (ISU)
Setting
E, 0
E, 0
1
4
90
60
3
Choices
Option
Description
E, 0 - 14
E - Auto-Discover
0 - Disabled (reminder off)
1 - 10 run time days
2 - 30 run time days
3 - 60 run time days
4 - 90 run time days
5 - 120 run time days
6 - 180 run time days
7 - 270 run time days
8 - 365 run time days
9 - 30 continuous days
10 - 60 continuous days
11 - 90 continuous days
12 - 120 continuous days
13 - 180 continuous days
14 - 365 continuous days
E, 0 - 3
E - Auto-Discover
0 - Disabled
1 - 90 continuous days
(30 run time days)
2 - 180 continuous days
(60 run time days)
3 - 365 continuous days
(90 run time days)
0, 1
0 - Conventional recovery
is activated
1 - Adaptive Intelligent
Recovery control is
activated
2, 4
2 - Two Periods available
(Wake, Sleep)
4 - Four Periods available
(Wake, Leave, Return,
Sleep)
50 - 90
Highest heating setpoint.
Temperature range (1°F
increments) of heating
setpoint.
60 - 99
Lowest cooling setpoint.
Temperature range (1°F
increments) of cooling
setpoint.
0 - 15
Minimum number of
minutes non-compressor
(heat) equipment is on.
13
TCONT900AC43UA
Comments
When set to Auto-Discover
(and the discovered value is
not 0=disabled), the
Comfort Control will display
the filter timer value it
receives from the
TM
ComfortLink
II
communicating filtering
device on the More screen.
To reset the filter timer of
TM
the ComfortLink
II
communicating filtering
device, simply press the
More key to access the filter
timer value and then press
the Reset key. If no
TM
ComfortLink
II
communicating filtering
device has been
discovered, the auto-
discovered value will default
to 0.
When not set to Auto-
Discover (and not set to
0=disabled), the Comfort
Control will display its
internal filter timer on the
More screen.
To reset the Comfort
Control's internal timer,
simply press the More key
to access the filter timer
value and then press the
Reset key.
When controlling humidifier
settings, use run time days.
Otherwise, use calendar
days.
Adaptive Recovery starts
recovery early to reach
setpoint by start of program
period.
Selection applies to all days
of the week.
Not shown if
nonprogrammable is
selected.
Shown in 1/2°C
Shown in 1/2°C
Pub. No. 18-HD32D1-2