Mitsubishi Electric MXZ-2HA40VF-E1 Service Manual page 15

Outdoor unit
Hide thumbs Also See for MXZ-2HA40VF-E1:
Table of Contents

Advertisement

Outdoor model
Outdoor unit power supply
Indoor units number
Piping total length
Connecting pipe length
Height difference (Indoor ~ Outdoor)
Height difference (Indoor ~ Indoor)
Function
Capacity Rated (Min.-Max.) *2
Breaker capacity
Power input (Total) *1, *2
Running current (Total) *1, *2
Power factor (Total) *1, *2
Starting current (Total) *1, *2
Coefficient of performance (C.O.P) (Total) *1, *2
Model
Output
Current *1, *2
Refrigeration oil (Model)
Model
Current *1, *2
Dimensions W x H x D
Weight
Air flow (Rated)
Sound level (Rated)
Fan speed (Rated)
Pre-charged refrigerant quantity (R32)
Max refrigerant quantity (R32)
*1 Measured under rated operating frequency.
*2 When connected with indoor units below.
MSZ-HR25VF + MSZ-HR25VF
NOTE: Test conditions are based on ISO 5151. (Refrigerant piping length (one way): 5 m)
COOLING INDOOR
Dry-bulb temperature 27.0 °C Wet-bulb temperature 19.0 °C
OUTDOOR Dry-bulb temperature 35.0 °C Wet-bulb temperature 24.0 °C
HEATING INDOOR
Dry-bulb temperature 20.0 °C
OUTDOOR Dry-bulb temperature 7.0 °C Wet-bulb temperature 6.0 °C
OBH828B
m
m
m
Refer to 8 REFRIGERANT SYSTEM DIAGRAM.
m
Refer to 8 REFRIGERANT SYSTEM DIAGRAM.
Cooling
kW
5.0 (1.1 - 5.4)
A
W
1,520
A
7.1 - 6.8 - 6.5 (220V - 230V - 240V) 7.2 - 6.9 - 6.6 (220V - 230V - 240V)
%
A
3.29
W
A
L
A
mm
kg
3
m
/h
1,962
dB(A)
47
rpm
890
kg
kg
15
MXZ-2HA50VF
Single phase
220 - 230 - 240 V, 50 Hz
2
Max. 30
Max. 20
Heating
6.0 (1.0 - 6.4)
15
1,540
97
7.6
SVB130FBBMT
1,300
6.75
0.35 (FW68S)
RC0J50-NA
0.35
800 x 550 x 285
37
2,082
0.9
0.9
3.90
51
940

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents