R-410A SEALED SYSTEM REPAIR
Replace 9k, 12k, and18k Cassette
Removal and Installation of Condensate Pump
1. Loose n the screws
holding condensat e pan .
2. Remove the
condensate pan .
3. Pull out the water
outlet pipe .
4. Lo osen the screws
holding the condensat e
pump .
5. Take out the pum p
and replac e it.
215
Step
Illustration
Use screwdriver to loosen
the
drain pan in place.
Carefully remove the
condensate pan.
Pull out the water outlet
Pipe.
Lo osen the screws holding
the condensate pump .
Take out the pum p and
replac e it.
Handli ng Instruction
screws holding the