Replace 18/24K Outdoor Unit Compressor And Motor - Friedrich Floating Air Pro Multi-Zone FPHMR42A3A Service Manual

Hide thumbs Also See for Floating Air Pro Multi-Zone FPHMR42A3A:
Table of Contents

Advertisement

R-410A SEALED SYSTEM REPAIR

Replace 18/24k Outdoor unit Compressor and Motor

Important: Befor e disassembly and assembly, mak e sure that the power to the system
has been disconnected and verified as voltage free.
Step
1.Remove external casing
2.Remove motor
3.Remove compressor
4. Assemble unit
209
Illustration
Handling Instruction
1. Remove the top cover, handle
and valve cover;
2. Remove the outer case and
right side plate.
1. Remove the blade nut and
then remove the blade;
2. Remove the motor from
motor supporter
1. Reclaim the refrigerant from
the entire system.
2. Unsolder the 4 -way valve
piping assy from compressor;
3. Remove the compressor
mounting bolts;
4. Carefully remove the
compressor from chassis.
Assemble the unit in the
reverse order of disassembly.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents