Electrical Adjustment Instructions - Toshiba RD-XV47KE Service Manual

Hdd & dvd / video cassette recorder
Hide thumbs Also See for RD-XV47KE:
Table of Contents

Advertisement

ELECTRICAL ADJUSTMENT INSTRUCTIONS

NOTE:
1.Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to do these adjustments only after
all repairs and replacements have been com-
pleted. Also, do not attempt these adjustments
unless the proper equipment is available.
2.To perform these alignment / confirmation proce-
dures, make sure that the tracking control is set in
the center position: Press either [PROGRAM
or [PROGRAM
] button on the front panel first,
then the [ O ] (VCR) button on the front panel.
Test Equipment Required
1.Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div.,
F-Range: DC~AC-20MHz
2.Alignment Tape (FL6A)
Head Switching Position Adjustment
Purpose:
To determine the Head Switching position during
playback.
Symptom of Misadjustment:
May cause Head Switching noise or vertical jitter
in the picture.
Test point
Adj.Point
VR501
J308( AV1-V-OUT )
(Switching Point)
TP504(RF-SW)
(BOARD
GND
POWER)
Measurement
Tape
Equipment
FL6A
Oscilloscope
Connections of Measurement Equipment
J308
BOARD
GND
POWER
TP504
All manuals and user guides at all-guides.com
NOTE: BOARD MEANS PRINTED CIRCUIT BOARD.
5 ? ? ]
Mode
Input
PLAY
-----
(SP)
Spec.
6.5H±1H
(416μs±64μs)
Oscilloscope
CH1
CH2
Trig. (+)
1-8-1
Figure 1
EXT. Syncronize Trigger Point
CH1
1.0H
6.5H±1H (416 μs ± 64 μs)
CH2
Switching Pulse
Reference Notes:
Playback the Alignment tape and adjust VR501 so that
the V-sync front edge of the CH1 video output wave-
form is at the 6.5H±1H (416μs±64μs) delayed position
from the rising edge of the CH2 head switching pulse
waveform.
0.5H
V-Sync
E3B90EA

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd-xv47kbRd-xv47kf

Table of Contents