Download Print this page

Battery Replacement - Klein VDV Scout Pro 3 Instruction Manual

Advertisement

COAX CABLE PROPERLY WIRED:
1. Loosen screw with No. 2 Phillips screwdriver and remove
2. Remove and recycle exhausted battery.
3. Install new 9-volt alkaline battery, with the wires running
4. Replace battery door and tighten screw. Do not overtighten.
Turn instrument off and disconnect any cables. Clean the instrument by using a damp cloth.
Do not use abrasive cleaners or solvents.
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose
to high temperatures or humidity. After a period of storage in extreme conditions exceeding the
limits mentioned in the Specifications section, allow the instrument to return to normal operating
conditions before using it.
TEST + MAP™ ID REMOTES (VDV501-2## SERIES)
Use for cable location identification mapping and continuity testing.
Remotes display on tester as Remote IDs #1-12.
1.800.561.8187
WIRE MAP AND DISPLAY EXAMPLES
COAX CABLE WITH AN OPEN:
Pass
ID
battery cover.
under the battery, towards the inside of the housing.
Do not place equipment and its accessories in the trash. Items must be properly disposed
of in accordance with local regulations. Please see www.epa.gov or www.erecycle.org
for additional information.
UPGRADE/REPLACEMENT REMOTES
RJ45 port
www.
NOTE: An
open fault
will also
Open
occur when
no remote is
connected to
the satellite
end of a video/
coax cable.

BATTERY REPLACEMENT

CLEANING
STORAGE
DISPOSAL / RECYCLE
2–6
F-connector port
.com
COAX CABLE WITH A SHORT:
Short
REMOTE ID NO.
PART NO.
1
VDV501-211
2
VDV501-212
3
VDV501-213
4
VDV501-214
5
VDV501-215
6
VDV501-216
7
VDV501-217
8
VDV501-218
9
VDV501-219
10
VDV501-220
11
VDV501-221
12
VDV501-222
2–6
VDV770-850
7–12
VDV770-851
information@itm.com
11

Advertisement

loading

This manual is also suitable for:

Vdv501-852Vdv501-853