ENGLISH
• MODE: The top line of the display shows what cable
• PASS/SPECIAL CABLES: "Pass"
• CABLE FAULTS: "Fail"
• VOLTAGE CHECK: A check for voltage on the RJ45 terminated data cable is performed before each test and if
• MEASUREMENT:
• LOCATION ID:
• BATTERY STATUS: The battery low icon
• TESTER-END WIRE MAP:
• REMOTE-END WIRE MAP:
• PoE INDICATORS:
• PoE ERROR INDICATOR:
LENGTH MEASUREMENT: The VDV Scout
length. One end of the cable should be connected to the corresponding port on the top of the tester. The other
end should be left disconnected or attached to the self-storing remote.
LENGTH CONSTANT: The length constant refers to the electrical characteristic of a cable used to characterize
length. Every cable has an associated length constant in units of picofarads per foot (pf/ft.). Setting the length
constant on the tester is important to obtaining an accurate cable length measurement from the VDV Scout
The default length constants are as follows: Voice: 17.0pF/ft.
The length constant can sometimes be provided by the manufacturer of the cable (see DISPLAYING/EDITING LENGTH
CONSTANT section). You may have to determine the length constant yourself (see DETERMINING AN UNKNOWN
LENGTH CONSTANT section). Length constants can range from 10pF/ft. to 40pF/ft.
Measurement accuracy is dependent on how close the tester can be set to the length constant of the cable being
measured and the consistency of the cable along its length.
The length constant can vary from cable to cable, even of the same type produced by the same manufacturer. It can also
vary over the length of one cable because the length constant is dependent on the physical properties of the cable, which
may not be consistent throughout the entire cable. The change in wire pair spacing through the cable can vary the length
constant along the length of the cable.
When setting the length constant using a length of cable, the cable should be at least 50 ft. long. This will yield a ±5%
uncertainty (1 in 50) of length constant accuracy. A longer cable reduces this uncertainty.
MEASURING LENGTH – VOICE OR DATA CABLES:
1. Press the Power button
2. Connect one end of the cable to the appropriate port: RJ45 port
3. Press the Length button
4. Press the Data button
5. Press the Data button
6. Read the length measurement as shown.
MEASURING LENGTH – COAX CABLES:
1. Press the Power button
2. Connect one end of the cable to the F-connector port
3. Press the Length button
4. Press the Video button
5. Read the length measurement as shown.
1.800.561.8187
4
type is being tested; voice (RJ11/RJ12)
(F-terminated coax)
or data (RJ45)
3
Hub Blink mode
4
or Tone mode
6
if the cable is a properly wired 4-pair T568A/B data
cable, a 3-pair one-to- one wired voice cable or a
video cable with no faults. In addition, "X-over"
illuminates if a properly wired cross-over (uplink)
cable is recognized, or "Rev"
8
illuminates if the
cable is a properly wired reverse-pinned voice cable.
The wire map will show actual pin connections.
"Shielded"
9
illuminates when a shielded data cable
is properly connected at both ends. It will be flashing
if there is a short to a wire in the cable along with that
pin number and the "Short"
11
indicator.
will illuminate only if the cable is not wired to one of the cabling standards. "Short" (two
10
wires making conductive contact)
11
not making connection at both ends of the cable)
type of fault(s) detected. See WIRING AND DISPLAY EXAMPLES section for wire standards and failure modes.
found, no test is run. If voltage is detected on the phone, coax or data testing ports, or if voltage over 70 Volts
is detected on the PoE testing port, the lightning bolt warning symbol
disconnected immediately from the source of the voltage.
15
Length mode: Length of cable run in feet or meters. PoE mode: Voltage.
16
The remote ID number will display here.
illuminate when the battery needs to be replaced. Results may be unreliable at this point.
Displays the pins on the tester end of the cable in order. These pins are mapped
18
to the pins on the remote-end shown directly below them on the LCD
Displays the corresponding pin on the remote-end. Dashed lines on this row
19
indicate shorted pins. No pin numbers displayed on this row line are open pairs.
20
Indicate PoE configuration. See chart on page 10 for details.
21
Indicates no PoE detected when test is initiated.
G
to turn tester on.
(if testing data cable), RJ12 port (if testing voice cable), located at the top
of the main tester body. Leave the other end of the cable unterminated.
F
to enter Length mode.
C
or Voice button
depending on the cable being tested, to begin the test.
C
repeatedly to select the pair of wires that
should be measured. The first functional pair is chosen by default.
G
to turn tester on.
located at the top of the main tester body.
Leave the other end of the cable unterminated.
F
to enter Length mode.
B
to begin the test.
www.
DISPLAY
1
11
1
, video
, and if
5
2
is activated.
will be displayed
6
Pass X-over Rev
10
Fail Short Split Open
7
12
14
15
1 2 3 4 5 6 7 8
18
19
, "Split" (wire pairs not maintained as pairs when terminated)
13
, or a combination of these will also illuminate to indicate the
illuminates when the battery is nearing depletion. The icon will
17
OPERATING INSTRUCTIONS
Pro 3 uses the capacitive properties of a cable to measure its
TM
Data: 15.0pF/ft.
A
,
NOTE: A voice or data cable under test can be
unterminated (open) or terminated by an RJ45
ID remote. If it is terminated by the self-storing
remote, the reading will be 1 to 2 ft. greater than
the actual measurement. In this case, subtract
1 to 2 ft. from the reading to obtain the actual
measurement. Coax cable under test maybe left
unterminated.
.com
2
7
3
8
11
4
9
5
Shielded
A
PoE
+
B
m
ID
ft
12
, "Open" (wires
14
will illuminate. The tester should be
Pro 3.
TM
Video: 15.0pF/ft.
Cable
Type
Indicates
Shielded
cable
Test Running
Remote ID#
Continuously
(if terminated)
Measured Length = 45 ft.