Download Print this page

Advertisement

Quick Links

VDV Scout
ENGLISH
INSTRUCTION MANUAL
• VOICE, DATA, AND VIDEO CABLE TESTING
• DETECTS SHORT FAULTS, OPEN FAULTS,
• POWER OVER ETHERNET (PoE)
• CABLE ID
• LENGTH MEASUREMENT
• TONE GENERATOR
• EXTRA-LARGE BACKLIT LCD
• HUB BLINK
• AUTO POWER-OFF
1.800.561.8187
Pro 3
TM
pg. 2
REVERSALS, MISWIRES, CROSSOVER
WIRING AND SPLIT PAIRS
www.
Pass X-over Rev
Fail Short Split Open
m
ft
1 2 3 4 5 6 7 8
information@itm.com
.com
VDV501-852
VDV501-853
Shielded
A
PoE
+
B
ID

Advertisement

loading

Summary of Contents for Klein VDV Scout Pro 3

  • Page 1 VDV Scout Pro 3 VDV501-852 VDV501-853 ENGLISH pg. 2 INSTRUCTION MANUAL • VOICE, DATA, AND VIDEO CABLE TESTING • DETECTS SHORT FAULTS, OPEN FAULTS, REVERSALS, MISWIRES, CROSSOVER Pass X-over Rev Shielded WIRING AND SPLIT PAIRS Fail Short Split Open • POWER OVER ETHERNET (PoE) •...
  • Page 2: General Specifications

    ENGLISH GENERAL SPECIFICATIONS The Klein Tools VDV Scout Pro 3 is a portable voice-data-video cable tester. It tests and troubleshoots RJ11, RJ12, RJ45, and F-connector terminated cables and provides tone generation for cable tracing. The VDV Scout Pro 3 also measures cable length, tests for shield, performs hub blink testing, and traces up to 19 locations (up to 5 locations with included remotes, additional remotes available separately).
  • Page 3: Keypad Function

    ENGLISH SELF-STORING TEST + MAP™ ID REMOTE (VDV501-210) Use for cable location identification mapping and/or continuity testing. Self-storing remotes display on tester as Remote ID #1. Included with all VDV Scout Pro 3 models. RJ11/12 port F-connector RJ45 port port TEST + MAP™...
  • Page 4 ENGLISH DISPLAY • MODE: The top line of the display shows what cable type is being tested; voice (RJ11/RJ12) , video (F-terminated coax) or data (RJ45) , and if Hub Blink mode or Tone mode is activated. • PASS/SPECIAL CABLES: “Pass” will be displayed Pass X-over Rev Shielded...
  • Page 5 OPERATING INSTRUCTIONS DISPLAYING/EDITING LENGTH CONSTANT: Follow these instructions to set the length constant based on a known value (for example, as given by the cable manufacturer). The VDV Scout Pro 3 stores a separate length constant for each of the three cable types (voice, data, and video).
  • Page 6 ENGLISH OPERATING INSTRUCTIONS TESTING CONTINUITY ON TERMINATED OR INSTALLED RJ45/RJ11/RJ12 CABLE (FIG. 1, FIG. 2): 1. Connect one end of the cable under test to the RJ45 port (if testing a data cable) or RJ11/RJ12 port (if testing a voice cable) located at the top of the main tester body. If testing a wall port, connect a known good patch cable from the wall plate to the appropriate port at the top of the main tester body.
  • Page 7 Pro 3's built-in analog tone generator. The tester will place a low-frequency voltage on the cable. By using an analog tone probe (Klein Tools VDV500-123, sold separately), a cable can be identified by the tone it is carrying. This technique only allows one cable to be traced per tone generator, but has additional benefits like the ability to trace unterminated cables of non-standard types.
  • Page 8 Data/Down button will change the pins or pairs of pins on which the tone is carried. 4. Use an analog tracing probe (Klein Tools VDV500-123 recommended, sold seperately) to determine the wire or wires on which the tone is being transmitted (see tone probe instruction manual for details).
  • Page 9 ‡NOTE: Only Klein Tools Universal RJ12 Jumper Cable (VDV726-125) or an approved equivalent should be used in the RJ45 jack of the Test + Map™ ID Remotes. Using a standard RJ11/12 patch cable in the RJ45 port on the tester could result in damaged contact pins.
  • Page 10 ENGLISH POWER OVER ETHERNET (PoE) REFERENCE CHARTS POWER OVER ETHERNET (PoE) REFERENCE CHARTS 10/100 10/100 1000 (1 GB) 1000 (1 GB) Mode B Mode A Mode B Mode A TIA/EIA-568 TIA/EIA-568 DC on Spares Mixed DC & Data DC & Bi-Data DC &...
  • Page 11: Battery Replacement

    WIRE MAP AND DISPLAY EXAMPLES COAX CABLE PROPERLY WIRED: COAX CABLE WITH AN OPEN: COAX CABLE WITH A SHORT: NOTE: An open fault Pass will also Open Short occur when no remote is connected to the satellite end of a video/ coax cable.

This manual is also suitable for:

Vdv501-852Vdv501-853