Stoelting CC Series Owner's Manual page 9

Table of Contents

Advertisement

Dimensions
width
height
depth
Weight
Electrical
circuit ampacity
(per barrel)
overcurrent protection
device (per barrel)
Hopper Condensing
Unit
Drive Motor
Cooling
Hopper Volume
Dimensions
Electrical
circuit ampacity
overcurrent protection
Refrigerant
Refrigerated Line
Owner's Manual #513642
Machine
42-1/2'' (108,0 cm)
61-7/8'' (157,2 cm)
47-1/8'' (119,7 cm)
1135 lbs (514,8 kg)
Air cooled units require one remote
condensing unit (with compressor) per
barrel. Condensing units #285092 and
#285093 ship from the factory with 20 lbs
of R-404A for up to a 50' line set. Add 1
lb of refrigerant for every 10' increase to
the line set. Line set max 100'. (Remote
condensers CU-0010 and CU-0020 do
not ship charged and require 24 lbs of
R-404A)
Remote Condensing Unit (1 per barrel)
width
height
depth
Weight
1 Phase, 208-230 VAC, 60Hz 3 Phase, 208-230 VAC, 60Hz
20A minimum
25A maximum
device
Charge
Sizes
CC404A
3 Phase, 208-240 VAC, 60Hz
9A minimum
15A maximum
1 Phase, 115 VAC, 60Hz
NEMA5-15P power cord provided
Four - 3 hp
Water cooled units are self contained and
require a Standard Hose Adapter water
fi tting and a 1/2" OD drain fi tting for each
barrel. They are charged with R-404A.
Maximum water pressure of 130 psi
Minimum water fl ow rate of 3 GPM
Four - 8.8 gallon (33,32 liters)
Condenser
37-3/4'' (95,9 cm)
17-1/4'' (43,7 cm)
28-1/4'' (71,7 cm)
222 lbs (100,7 kg)
R-404A
20 lbs. (Charged at Factory)
Liquid Line - 3/8"
Suction Line - 7/8"
3
with crate
50'' (127,0 cm)
67'' (170,2 cm)
60'' (152,4 cm)
1210 lbs (548,8 kg)
Ideal EWT of 60°-80°F
15A minimum
20A maximum
CC Model Machines

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc101Cc202Cc303Cc404

Table of Contents