J.
Front Door Safety Switch
The front door safety switch prevents the auger
from turning when the front door is removed. The
switch is open when the door is not in place and
closed when the door is properly installed.

3.3 SANITIZING

Sanitizing must be done after the machine is cleaned and
just before the hopper is fi lled with mix. Sanitizing the night
before is not effective. However, you should always clean
the machine and parts after each use.
THE UNITED STATES DEPARTMENT OF AGRI-
CULTURE AND THE FOOD AND DRUG ADMIN-
ISTRATION REQUIRE THAT ALL CLEANING AND
SANITIZING SOLUTIONS USED WITH FOOD
PROCESSING EQUIPMENT BE CERTIFIED FOR
THIS USE.
When sanitizing the machine, refer to local sanitary regu-
lations for applicable codes and recommended sanitizing
products and procedures. The frequency of sanitizing
must comply with local health regulations.
Mix sanitizer according to manufacturer's instructions to
provide a 100 parts per million strength solution. Mix sani-
tizer in quantities of no less than 2 gallons (7.5 liters) of
90° to 110°F (32° to 43°C) water. Allow sanitizer to contact
the surfaces to be sanitized for 5 minutes. Any sanitizer
must be used only in accordance with the manufacturer's
instructions.
In general, sanitizing may be conducted as follows:
A.
Prepare Stera-Sheen Green Label Sanitizer
or equivalent according to manufacturer's
instructions to provide a 100ppm strength solution.
Mix the sanitizer in quantities of no less than 2
gallons of 90° to 110°F (32° to 43°C) water. Any
sanitizer must be used only in accordance with
the manufacturer's instructions.
Figure 3-3 Flow Control Assembly
Owner's Manual #513642
B.
Place the tapered end of the fl ow valve into the
hopper drain hole with the arm pointing towards
the left. Connect the fl ow control rod to the fl ow
valve and the fl ow valve arm (Fig. 3-3).
C.
Make sure the fl ow control valve is shut by turning
the control knob counterclockwise to the 12:00
position.
D.
Place a bucket under the slide.
E.
Pour the sanitizer into the hopper.
A small amount of sanitizer may drain into the
bucket with the fl ow control shut and may seep out
of the rear seal.
F.
Place the Freezing Cylinder OFF-ON switch in
the ON position and press the PURGE/CLEAN
button. The display will read PURGE.
G.
Press and hold the PURGE/CLEAN button for 3
seconds. The display will read CLEAN and a 10
minute timer will start.
H.
Turn the fl ow control knob fully open (clockwise)
to drain the sanitizer from the freezing cylinder.
I.
Clean sides of hopper, fl ow valve and underside
of hopper cover using a sanitized soft bristle brush
dipped in the sanitizing solution.
J.
When the sanitizer has drained from the hopper,
press and hold the PURGE/CLEAN button for
3 seconds to stop the auger. Allow the freezing
cylinder to drain completely.
K.
Shut off the fl ow control valve by turning the
fl ow control knob counterclockwise to the 12:00
position.

3.4 FREEZE DOWN AND OPERATION

This section covers the recommended operating proce-
dures to be followed for the safe operation of the machine.
A.
Sanitize just prior to use.
Make sure the fl ow control assembly is in place
before adding mix and that the fl ow control knob is
set to the 12:00 position.
B.
Fill the hopper with 5 gallons (18.9 liters) of pre-
chilled (40°F or 4°C) mix.
E.
Place the Freezing Cylinder OFF-ON switch in
the ON position. The display will read STANDBY
MODE.
F.
Press the PUSH TO FREEZE button. The display
will read CUSTARD and a bar on the second line
will start to fi ll. On the right cylinder the product
type can be changed by moving the Product
Selector switch to the Product 2 position.
15
NOTE
NOTE
CC Model Machines

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cc101Cc202Cc303Cc404

Table of Contents