  • Page 1 Model: PG4000iSR Inverter Gasoline OPERATOR’S MANUAL Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. support@pulsar-products.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Introduction ................................... 3 Parts Ordering / Customer Service..........................3 Safety Rules ..................................4 Safety Symbols ................................4 Safety Instructions ..............................4 Features ....................................7 Control Panel Functions ..............................8 ON/OFF Start Switch ..............................
  • Page 3: Introduction

    INTRODUCTION Thank you for purchasing this superior quality portable generator from PULSAR PRODUCTS INC. When operating and maintaining this product as instructed in this manual, your generator will give you many years of reliable service. This generator is an engine-driven, portable generator.It is designed to supply electrical power to operate tools, appliances, camping equipment, lighting, or serve as a back up power source during power outages.
  • Page 4: Safety Rules

    SAFETY RULES Safety Symbols Indicates a potentially hazardous WARNING! situation which could result in serious injury or death if not avoided. Indicates a potentially hazardous CAUTION! situation which could result in damage to equipment or property. Toxic Fumes Risk of explosion Risk of electric shock Hot surface Safety Instructions...
  • Page 5 SAFETY RULES Never exceed generators wattage / amperage capacity. This could damage the generator WARNING! and / or connected electrical devices. • Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator. Never start or stop engine with electrical devices plugged in to the receptacles. Failure to WARNING! do so could damage the generator and / or connected electrical devices.
  • Page 6 • Never insert objects through cooling slots. WARNING! Never operate this unit if there are any broken or missing parts and only use PULSAR PRO- replacement parts specifically designed for this unit. DUCTS INC. • Improper treatment of generator can damage the unit and shorten its life.
  • Page 7: Features

    FEATURES Never Flat Wheels: Control Panel: Telescoping Handle: Oil Access Cover: Carry Handle: Recoil Handle: Battery Access Panel: Fuel Cap: Automatic Choke: Engine Service Panel: Muffler and Spark arrestor: CONTROL PANEL 30 A RV OUTLET 2-120V OUTLETS AC & DC CIRCUIT BREAKERS GROUND TERMINAL PARALLEL TERMINALS PUSH START...
  • Page 8: Control Panel Functions

    CONTROL PANEL FUNCTIONS ON/OFF Start Switch Start Switch “OFF” When the Start Switch is in the “OFF” position the fuel valve is switched off and the engine will not run. Start Switch “RUN” When the Start Switch is in the “RUN” position the fuel valve is switched on and the engine can run.
  • Page 9: Indicator Lights

    CONTROL PANEL FUNCTIONS Note: The engine overload indicator light may turn on for a few sec- onds when attaching a load due to a power surge. This is normal. AC Pilot Indicator Light The green AC Pilot Indicator Light comes on when the engine starts and generates power.
  • Page 10: Parallel Outlets

    Located just above the Ground Terminal, the generator’s Parallel Outlets enable a user to run two PG2000iS generator’s simultaneously. This operation requires special cables. When operating parallel generators, the rated output is 3.0kVA and the rated current is 25A/120VAC. For cables and instructions consult a PULSAR dealer for a PARALLEL OPERATION C C C...
  • Page 11: Assembly

    ASSEMBLY Connecting Generator to an Electrical System • If connecting generator to a building’s electrical system for standby power, The power from the generator must be isolated from the circuit breaker or alternative power source. The connection must comply with all electrical codes and applicable laws.
  • Page 12: Adding / Checking Oil

    ASSEMBLY Connecting the Battery • Unclip the battery access panel on the back of the unit next to the muffler • Securely tightened battery cables to the battery post accordingly (negative cable to negative post) Positive cable to positive post. (see illustartion) Negative (Red) NOTE: The electric start generator is equipped...
  • Page 13: Operation

    OPERATION Grounding the Generator To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel Functions pg. 10. Standard Atmospheric Conditions Ambient Temperature: 77ºF (25ºC) Barometric Pressure: 100kPa Relative Humidity: 30% Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity, or altitude are higher than standard atmospheric conditions, the generator’s output will be reduced.
  • Page 14: How To Stop Engine

    OPERATION How to Stop Engine • Turn the Economy switch to the “OFF” position. Disconnect any electronic device. All loads MUST be disconnect from the generator. Never start or stop the engine • with electrical devices plugged in to the receptacles. •...
  • Page 15: Charging A 12 Volt Battery

    OPERATION Charging a 12 Volt Battery This generator can be used to charge a 12 volt automotive or storage battery by taking the following steps: ONLY level is low. Never add tap water. 1. Use a wire brush to clean battery terminals if corroded. 2.
  • Page 16: Ac Parallel Operation

    OPERATION AC Parallel Operation It is possible to connect two PG4000iSR generators to each other, using a parallel cable kit, to increase available power output. • Connect PARALLEL OPERATION CABLES to two PG4000iSR generators according to the instructions provided with the cable kit.
  • Page 17: Don't Overload Generator

    OPERATION Don’t Overload Generator Make sure you can supply enough rated watts for all electronic devices connected to the generator. Rated watts refer to the power a generator must supply to keep a device running. Surge watts refer to the power a generator must supply to start an electronic device.
  • Page 18: Maintenance

    Before inspecting or servicing this machine, make sure the engine is off and no parts are WARNING! moving. Disconnect the spark plug wire and move it away from the spark plug. If you are unsure of how to perform a maintenance task, have the unit serviced by a PULSAR CAUTION! dealer...
  • Page 19: Checking Spark Plug

    MAINTENANCE Checking Spark Plug • Remove the Engine Service Panel to gain access to the Spark plug • Remove cap. Then remove spark plug cap. • Disconnect the spark plug wire from the spark plug. • Before removing the spark plug, clean the area around its base to prevent debris from entering the engine.
  • Page 20: Changing Oil

    MAINTENANCE Changing Oil • Place generator on a level surface. • Run the generator for several minutes until the engine is warm. Turn off generator. • Remove screws, then remove outer casing side cover. • Remove the crankcase dipstick. • Place an oil pan underneath the engine.
  • Page 21: How To Clean Air Filter

    MAINTENANCE Air Filter • To clean, remove the screws then remove outer casing. • • Remove the foam element. • Wash the foam element in solvent and let dry. • Unlock Air Filter Cover Do not run the generator without reinstalling the foam element or excessive piston and CAUTION! cylinder wear may result.
  • Page 22: How To Clean Fuel Filter

    MAINTENANCE Fuel Tank Filter • • • • • Install fuel cap. Fuel Filter • To clean, remove screws, remove outer casing, and drain fuel. • Lift and hold onto the clamp, then remove hose from tank. • • • •...
  • Page 23 MAINTENANCE Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine cool WARNING! before transporting or storing the generator. Take care not to drop or strike the generator when transporting. Do not place heavy objects on the CAUTION! generator.
  • Page 24: Troubleshooting

    9. Add oil level. 10. Engine has flooded 10. Wait 5 minutes and recrank engine 11. Faulty ignition 11. Contact PULSAR dealer 1. Generator is overloaded Engine lacks power 1. See pg 17 “Don’t overload generator” 2.Clean or replace fuel filter 2.Clogged fuel filter...
  • Page 25: Specifictions

    If there is any question concerning this manual, please consult a PULSAR dealer. This manual should be considered a permanent part of this product and should remain with this product when resold.
  • Page 26: Wiring Diagram

    WIRING DIAGRAM...
  • Page 27: Warranty

    • Consumer is responsible for presenting any problems with the generator to an authorized PULSAR Service Center as soon as the problem exists. Warranted repairs will be completed in a reasonable period of time, not to exceed 30 days.
  • Page 28 Take the original receipt and product to the place of purchase or mail the original receipt and product to the address found on the web site if purchased on-line. PULSAR recommends you retain all of your receipts covering the purchase and maintenance of your Portable Generator, but will not deny you warranty coverage as long as proof of purchase or service can be obtained.