Aqua Lung CONSHELF XIV Technical Maintenance Manual page 18

First and second stage
Hide thumbs Also See for CONSHELF XIV:
Table of Contents

Advertisement

18
DESCRIPTION (KEY NUMBER)
Spring retainer (28)
Second-stage Inlet Fitting (11)
Hose fittings (26)
Port plugs (19, 23, 24, 22)
DIN adapter body (41)
DIN handwheel retainer (38)
TEST
Leak Test
Intermediate Pressure
Intermediate Pressure
Creep
Opening effort
Purge flow
Table 4 - Torque Specifications
Table 5 - Test Bench Specifications
CONDITION
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Inlet 2,500-3,000 (±100) psig
Conshelf XIV Service Manual
TORQUE
25±2 foot-pounds
55±5 inch-pounds
40 inch-pounds
15 inch-pounds
20±2 foot-pounds
15±2 foot-pounds
ACCEPTABLE RANGE
No leaks allowed
Standard: 140±5 psig
Supreme & 300 Bar: 125±5 psig
5 psi max between 5 to 15 seconds after cycling
(purging) regulator
0.6 to 1.5" of water (Standard)
1.2 to 2.1" of water (Octopus)
+5.0 SCFM (142 L.P.M.) Minimum

Advertisement