Service and maintenance
144

Cab

A
Cover
B
Nuts
C
Prefilter
D
Side guard
E
Casing
F
Main filter
Cab
Cab, ventilation filters
The machine is equipped with two ventilation filters in the cab, one
prefilter and one main filter. The clogging up of the filters is entirely
dependent on the working environment of the machine. The
prefilter should be checked and cleaned when required.
IMPORTANT! The cab filters are only intended to separate
particles (dust) from the air. Any dangerous gases are not
trapped by the filter.
Cab, replacing prefilter
Replace the filter every 1000 hours.
1 Remove cover (A).
2 Slacken nuts (B).
3 Remove prefilter (C).
Cab, cleaning prefilter
Carefully shake the filter without damaging it – avoid cleaning with
compressed air, vacuum cleaner or water.
IMPORTANT! Use personal protective equipment, e.g.
approved respirator, when cleaning the filter.
Cab, replacing main filter
Replace the filter every 2000 hours.
1 Remove side guard (D).
2 Detach casing (E).
3 Remove main filter (F).
NOTE! The main filter should not be cleaned, but must be
replaced.
Take care of filters/oils/liquids in an environmentally safe way,
see page 91.