SANITIZING
9. Turn both selector switches to "CLEAN" and allow the
beaters to run for 5 minutes. Check for leaks around the
head, drain tube, clamps and MTS.
10. Drain the solution from the cylinders by slowly pulling
down on the dispense handles. NOTE: Some sanitizer
will remain in hoses and cylinders.
11. Leave the handles down, and turn the selector switches
to "OFF". Let the MTS force all possible sanitizer out of
the freezing cylinders.
Failure to completely remove sanitizer or water from
the freezing cylinder before placing in "AUTO" will
damage the freezer.
12. Turn the MTS switches to "OFF".
13. Remove the mix inlet tubes, holding the top 6-inch
portion only.
14. Remove the mix containers and empty any remaining
sanitizer.
Priming The Freezer
1.
Make sure that your hands, forearms, and all freezer
assemblies are sanitized.
2.
Holding the top 6-inch portion only, insert the pickup
tubes into the sanitized mix container through the small
hole in the rear cover and set containers in the cabinet.
3.
Fill the mix containers with mix and install the front
covers.
4.
Insert the low mix probes through the large hole in the
rear cover, and connect the probe cords to the probes
and to the back of the cabinet.
5.
Turn the cabinet switch to "ON" and close the cabinet
door.
20
(continued)
Important:
Priming The Freezer
(continued)
6.
Place an empty container under the dispensing head
on the drip tray.
7.
Open the side plungers and air bleed plugs.
8.
Turn the MTS switches to "ON" and allow the mix to
push the remaining sanitizer from the cylinders through
the plunger openings.
9.
Close the side plungers when pure mix is coming out.
Important:
Failure to completely remove sanitizer or water from
the freezing cylinder before placing in "AUTO" will
damage the freezer.
10. After mix appears at the bottom of the head (approxi-
mately 50–55 seconds), close the air bleed plugs and
wait for the MTS to fill the cylinders and shut off.
11. After the MTS has cycled off (approximately 30 seconds)
turn both selector switches to "AUTO", both DAY/NIGHT
switches to "DAY", and both MTS switches to "ON".
12. Allow the freezer to cycle for 15 minutes. Sanitize the
nozzles and install on the head. The product is now
ready to serve.
Problem? Contact your local authorized distributor or the
freezer manufacturer, Electro Freeze Service Department,
2116 Eighth Avenue, East Moline, IL 61244, (309) 755-
or FAX (309) 755-9858