Advertisement

Quick Links

INSTALLATION, SERVICE & PARTS MANUAL
877-24PUMPS • www.powerflopumps.com
PF4SCC
Series:
4.2/4.8HP, 3PH, 230/460V
1150/1750 RPM, 60 Hz
PF4SCD
Series:
4.2/4.8/7.1HP, 3PH, 230/460V
1150/1750 RPM, 60 Hz
PF4SCE
Series:
4.2/12.9/17.7HP, 3PH, 230/460V
1150/1750 RPM, 60 Hz
PF4SCF
Series:
4.2/8.9/17.7/29.9HP, 3PH, 230/460V
1150/1750 RPM, 60 Hz
ISP No: PFcutter-ISP - 1/2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PF4SCC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Power-flo PF4SCC Series

  • Page 1 INSTALLATION, SERVICE & PARTS MANUAL PF4SCC Series: 4.2/4.8HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz PF4SCD Series: 4.2/4.8/7.1HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz PF4SCE Series: 4.2/12.9/17.7HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz PF4SCF Series: 4.2/8.9/17.7/29.9HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz 877-24PUMPS •...
  • Page 2: General Safety Information

    PHASE: ______ HP: _________________ vary depending on usage and location. appropriate lifting device. ® Power-Flo is a registered trademark of Power-Flo Technologies Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Alteration Rights Reserved.
  • Page 3 PF4SCE Series: OPTIONAL Seal Materials, Additonal Cable, EQUIPMENT 4.2/12.9/17.7HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz MAX FLOW 4500 GPM PF4SCF Series: MAX HEAD 295 TDH 4.2/8.9/17.7/29.9HP, 3PH, 230/460V 1150/1750 RPM, 60 Hz Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 4: Specifications

    , 0.457 O.D. (14/3, SO, 0.53 O.D.) NOTE: The use of a 4” Break Away Fitting is required with these pumps. NOTE: A relay is required for use with Moisture Sensor, see page 25. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 5 PF4SCC - 1150 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 6 PF4SCC - 1750 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 7 , 0.457 O.D. (14/3, SO, 0.53 O.D.) NOTE: The use of a 4” Break Away Fitting is required with these pumps. NOTE: A relay is required for use with Moisture Sensor, see Page 25. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 8 PF4SCD - 1150 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 9 PF4SCD - 1750 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 10 , 0.457 O.D. (14/3, SO, 0.53 O.D.) NOTE: The use of a 4” Break Away Fitting is required with these pumps. NOTE: A relay is required for use with Moisture Sensor, see Page 25. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 11 PF4SCE - 1150 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 12 PF4SCE - 1750 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 13 , 0.457 O.D. (14/3, SO, 0.53 O.D.) NOTE: The use of a 4” Break Away Fitting is required with these pumps. NOTE: A relay is required for use with Moisture Sensor, see Page 25. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 14 PF4SCF - 1150 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 15 PF4SCF - 1750 RPM Submersible Cutter Pumps Performance Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 16: Receiving And Installation

    The sump or basin shall be sealed could clog a standard sewage pump. and vented in accordance with local plumbing codes. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 17: Electrical Connections

    Figure 2 work properly. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 18: Maintenance

    Check impeller for binding. Assemble volute (40) onto motor assembly with screws (45) and washers (47). Apply thread locking compound on screws (45). Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 19 (10) for inspection, by T5 & T8 Together first disconnecting power, remove cap T6 & T9 Together screws (45) and washers (47) from volute (40). Lift motor assembly from volute and remove impeller. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 20 On some models, first slide bearing cap Reassembly: (4) onto shaft. Apply adhesive compound together. to the shaft and press lower bearing (11) Lower seal - Clean and oil seal cavity in on the motor shaft. intermediate (2). Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 21 Assemble upper seal as outlined be replaced. Check that moisture sensor above. wires are secured to the electrode (36). Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 22: Repair Parts

    For Repair Part Please supply: Model Number and MFG Date as shown on Repair Parts Name Plate, and Part Description and Part Number as shown on Parts List. 132 Frame Figure 6 Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 23 Submersible Cutter Pumps For Repair Part Please supply: Model Number and MFG Date as shown on Repair Parts Name Plate, and Part Description and Part Number as shown on Parts List. Figure 7 Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 24 Power cable PF0-1852301 11X4G1.5 PF0-1852322 4G6 PF0-1852341 4G10 Ground Wire connector Cable connector PF0-1861304 PF0-1861720 N21M PF0-186N29M Wire connector Control cable PF0-1852301 11X4G1.5 PF0-1852301 4G1.5 PF0-1852301 Description sizes in Metric Aquire hardware locally. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 25 Recommended Moisture & Temperature Sensor Relays for control panel (or equal): P/N: PF0861 - B/W 1500-D-L1-S90C rated for 25 volt amperes, 115 volt input, 500 volt output (one per pump). P/N: PF0876 - Siemens 3TX7114-5DF13 (one per pump). Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 26 PF4SCC, 4SCD, 4SCE, 4SCF Submersible Cutter Pumps Notes: Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 27: Troubleshooting Chart

    NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty.
  • Page 28: Limited Warranty

    Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...

This manual is also suitable for:

Pf4scd seriesPf4sce seriesPf4scf series

Table of Contents