Power-flo PFS411HTCE-2 Series Installation, Service & Parts Manual

0.4 hp • 1750 rpm • 60 hz submersible effluent, sump & sewage pump high temperature

Advertisement

Quick Links

INSTALLATION, SERVICE & PARTS MANUAL
Series:
PFS411HTCE-2
0.4 HP • 1750 RPM • 60 Hz
Submersible Effluent,
Sump & Sewage Pump
High Temperature
Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com
ISP No: PFS411HTCE-2 - 9/2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PFS411HTCE-2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Power-flo PFS411HTCE-2 Series

  • Page 1 INSTALLATION, SERVICE & PARTS MANUAL Series: PFS411HTCE-2 0.4 HP • 1750 RPM • 60 Hz Submersible Effluent, Sump & Sewage Pump High Temperature Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com ISP No: PFS411HTCE-2 - 9/2020...
  • Page 2: General Safety Information

    Requirements may vary depending on usage and location. ® Power-Flo is a registered trademark of Power-Flo Technologies Inc. Other brand and product names are trademarks or registered trademarks of their respective holders. Alteration Rights Reserved. 4/11, 5/12, 9/2020...
  • Page 3: High Temperature

    NEMA Start Winding Resistance Cord Cord Cord MODEL HP Hz Amps Rotor Amps Code MAIN -- START Type Size O.D. PFS411HTCE-2 4/10 60 115/1 1750 10.0 24.5 1.6 -- 18.5 SJOOW 16/3 0.325 Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 4 PFS411HTCE-2 Submersible Effluent, Sump & Sewage Pumps Dimensions & Performance - High Temp Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 5: Receiving And Installation

    9” for HTCE a dirt bottom. The legs will sink into the dirt and the suction will become plugged. Bottom of Feet Figure 1 Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 6: Installation & Service

    Oil level and operates on the combined effect of should be just above the motor when temperature and current. pump is in vertical position. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 7 9. Remove screws (4) and lift motor around the sealed areas above the oil Overfilling oil voids warranty. housing and motor from seal plate (8). level and inspect joints for “air bubbles”. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 8 IMPORTANT! - All parts must be (15F) and gland nut (15E) into upper clean before reassembly. housing (17) and reconect wires to cord Handle seal parts with extreme set. care. DO NOT damage lapped surfaces. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 9: Repair Parts

    Submersible Effluent, Sump & Sewage Pumps For Repair Part Please supply: Model Number and MFG Date as shown on Repair Parts Name Plate, and Part Description and Part Number as shown on Parts List. Figure 5 Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 10 Spring Washer Motor Housing Mechanical Seal PF068988SK Capscrew - Torque to 25 Ft-Lbs Lockwasher V-ring PF068053A Spacer Seal PF63PFS4103 Impeller PF089369TG Strainer 5000005 Mechanical Float, High Temp., 15 Ft. PF059-3640 Cable clamp Capscrew Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...
  • Page 11: Troubleshooting Chart

    NOTE: Power-Flo Pumps & Systems assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other than at Power-Flo Pumps & Systems or its authorized service centers, automatically voids warranty.
  • Page 12: Limited Warranty

    Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Power-Flo Pumps & Systems • 877-24PUMPS • www.powerflopumps.com...