3. Operations

3.1. Initiating Encoding

Once the Encoder is connected as described in Section 2, follow these instructions to begin
encoding:
1. Push the Enable/Bypass push button on the front panel to the 'in' position to enable Encoding
mode.
2. The LCD will then display "Encoding:" and a station specific message (station information).
3. The Encoding Status LED will display an unblinking green light to indicate normal operation,
and the relays will switch from bypass mode to encoding mode. An audible click may be
heard.
The SGE can be removed from the signal path and put into Bypass mode by pushing the
Enable/Bypass push button on the front panel to the 'out' position. This connects the input connectors
directly to their respective output connectors. See Section 3.3.2 for more information.

3.2. Immediately After Placing the Encoder On-Air

IMPORTANT: Before the installation of this Encoder is considered complete, Nielsen Audio requires
that a quality analysis check be performed on the encoded audio. The time required per Encoder is
minimal. Please call your Nielsen Audio contact to arrange this test.

3.3. Bypass Features

In bypass mode, signals input to the SGE pass through the device unchanged. The SGE provides
bypass modes for different circumstances as described in the three sections below.