Table 1: DB9 Pinouts for Remote Monitoring of Encode/Bypass Status

Pin 4
Pin 7

Figure 6: DB9 Pinouts for Remote Bypass Monitoring

The pins are connected to an internal relay of the Encoder. The relay contacts are rated at 0.3A
max, 24VDC.
This outlet also provides access to a bypass mode remote control functionality and an alarm
status remote monitoring functionality. For more information on these features, see Section 3.3.4
and Section 3.4.
9. If the optional Time Decoder Input is enabled: To ensure that the Encoder will synchronize
to the station clock upon boot-up, one of the supported time code sources must be properly
connected to the SGE time code input. For more information, see Appendix "
Optional Time Decoder Input
10. Connect the power cord to the SGE to the same plug strip that supplies power to the
instruments that will be connected to the input and output connectors of the SGE. The SGE
will turn on when power is supplied via the power cord.
11. The SGE is shipped with the Enable/Bypass push button on the front panel set in the 'out'
position to put the Encoder into bypass mode. At initial power-on, the LCD will display
"Bypass Mode Encoder Disabled". When in bypass mode, the Encoder does not encode
incoming signals, but allows them to pass through to the output unchanged. For more
information, see Section 3.3.2
12. To start encoding, see the instructions in Section 3.1
Status = ENCODE
Open to pin 3
Shorted to pin 3
."
Copyright © 2014 The Nielsen Company. All rights reserved.
Status = BYPASS
Shorted to pin 3
Open to pin 3