Figure 2-1 Rating label and product identification
Product line:
Frame size:
:
Voltage rating
1 - 100 V (100 - 120
±
10 %)
2 - 200 V (200 - 240
±
10 %)
4
- 400 V (380 - 480
±
10 %)
5 - 575 V (500 - 575
±
10 %)
6 - 690 V (500 - 690
±
10 %)
3
Mechanical installation
The drives can be panel mounted with 0 mm space between the drives. For further information on
mechanical installation refer to the Unidrive M300 User Guide.
B
A
Cover
release
B
To remove the terminal cover, use a flat bladed screwdriver to rotate the terminal cover locating clip
by approximately 30° in a counter clockwise direction, and then slide the cover down.
H
Drive
Size
mm
in
mm
1
160
6.30
75
2
205
8.07
78
3
226
8.90
90
4
277 10.91
115
Table 3-1 Recommended torque settings
Model size
All
1
2, 3, 4
2
Derivative
Electrical Specifications
M300 -
03
4
A
W
D
in
mm
in
mm
2.95
130
5.12
143
3.07
150
5.91
194
3.54
160
6.30
215
4.53
175
6.89
265 10.43
Terminal block description
Control terminals
Relay terminals
Power terminals
00073
A
M2
H M1
W
M2
M1
M2
in
mm
in
5.70
53
2.08
7.63
55
2.17
8.46
70.7
2.80
86
3.40
Drive Format :
A – AC in AC out
Current Rating :
Heavy Duty current rating x10
D
∅
A
mm
in
mm
in
5
0.2
5
0.2
0.00
0.00
5
0.2
6
0.23
Torque settings
0.2 N m (0.15 Ib ft)
0.5 N m (0.37 Ib ft)
0.5 N m (0.37 Ib ft)
1.4 N m (1.03 Ib ft)
Unidrive M300 Quick Start Guide
Issue Number: 1
B
mm
in
100
3.93
Need help?
Do you have a question about the 01100017 and is the answer not in the manual?
Questions and answers