Affixing the type plate

Fig. 18

Connecting the pellet supply and return air hoses

When installing the hoses, note the following:
Choose the shortest route to the boiler.
Height differential: Max. 5 m
Hose length to boiler: Max. 15 m
Note
Long hoses increase wear on the motor.
Install the hoses such that they are not under ten-
sion.
Never kink hoses. Bending radius: Min. 300 mm.
Route the hoses so they are as straight and level as
possible. If the hoses are laid such that they climb
and fall repeatedly, there is a risk of blockage.
Earth the hoses to prevent static load.
Do not subject hoses to temperatures in excess of
60
C.
°
Affix the type plate to the l.h. casing panel.
Once installed, the hoses must not be in contact with
hot components. Allow adequate clearance.
The pellet supply hose must be a single piece. The
return air hose may consist of several pieces. Use
metal connection pieces to ensure continuous earth-
ing.
Never route hoses outdoors (risk of becoming brittle
due to UV radiation).
Never route hoses so they are touching walls (risk of
sound transmission during pellet transport).
Secure hoses with clips at least every 1000 mm.
Note
We recommend fitting the clips of the hoses with
anti-vibration rawl plugs.