Viessmann Vitoladens 300-W Installation And Service Instructions For Contractors page 45

Wall mounted oil condensing boiler for the combustion of fuel oil to din 51603-1 el (low sulphur)
Table of Contents

Advertisement

Coding level 1
(cont.)
Coding in the delivered condition
Weather-compensated/room temperature hook-up
b0:0
With remote control: heating mode/
reduced mode: weather-compen-
sated (change the code only for
the heating circuit with mixer)
Economy function room temperature
b5:0
With remote control: no room tem-
perature-dependent heating circuit
pump logic function (change code
only for heating circuit with mixer)
Parameter address
With heating circuit pump logic function:
b5: ...
Heating circuit pump "OFF"
1
RT
2
RT
3
RT
4
RT
5
RT
6
RT
7
RT
8
RT
Coding in the delivered condition
Min. supply temperature heating circuit
C5:20
Electronic minimum flow tempera-
ture limit 20 °C
Heating circuit max. supply temperature
C6:74
Electronic maximum flow tempera-
ture limit set to 74 °C
Operating program - changeover
d5:0
External operating program
changeover switches operating
program to "Constant operation at
reduced room temperature" or
"Standby mode"
Ext. heating program changeover to heating circuit
d8:0
No operating program changeover
via EA1 extension
RT
+ 5 K
>
actual
set
RT
+ 4 K
>
actual
set
RT
+ 3 K
>
actual
set
RT
+ 2 K
>
actual
set
RT
+ 1 K
>
actual
set
RT
>
actual
set
RT
- 1 K
>
actual
set
RT
- 2 K
>
actual
set
Possible change
b0:1
Heating mode: weather-compensa-
ted
Reduced mode: with room tempera-
ture hook-up
b0:2
Heating mode: with room tempera-
ture hook-up
Reduced mode: weather-compensa-
ted
b0:3
Heating mode/reduced mode: with
room temperature hook-up
b5:1
For heating circuit pump logic func-
to
tion, see the following table:
b5:8
Heating circuit pump "ON"
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
RT
< RT
actual
set
Possible change
C5:1
Minimum limit adjustable from 1 to
to
127 °C (limited by boiler-specific pa-
C5:127
rameters)
C6:10
Maximum limit adjustable from 10 to
to
127 °C (limited by boiler-specific pa-
C6:127
rameters)
d5:1
The external operating program
changeover switches to "Constant
operation with standard room tem-
perature" (subject to coding ad-
dresses 3A, 3b and 3C)
d8:1
Operating program changeover via
input DE1 at EA1 extension
d8:2
Operating program changeover via
input DE2 at EA1 extension
d8:3
Operating program changeover via
input DE3 at EA1 extension
Codes
+ 4 K
+ 3 K
+ 2 K
+ 1 K
- 1 K
- 2 K
- 3 K
45