ELECTRIC SHOCK HAZARD
This equipment must be
electric shock.
Turn off and disconnect power cord before servicing equipment.
Connect only to grounded electrical outlets.
Use only 3-wire extension cords.
Ensure ground prongs are intact on power and extension cords.
Do not expose to rain. Store indoors.
GROUNDING
This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk
of electric shock by providing an escape wire for the electric current. This product is equipped with a
cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Improper installation of the grounding plug is able to result in a risk of electric shock.
When repair or replacement of the cord or plug is required, do not connect the grounding wire to
either flat blade terminal.
The wire with insulation having an outer surface that is green with or without yellow stripes is the
grounding wire.
Check with a qualified electrician or serviceman when the grounding instructions are not
completely understood, or when in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a
qualified electrician.
This product is for use on a nominal 120V circuit and has a grounding plug similar to the plugs
illustrated in the figure below.
Only connect the product to an outlet having the same configuration as the plug.
Do not use an adapter with this product.
Extension Cords:
Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle that
accepts the plug on the product.
Make sure your extension cord is not damaged. If an extension cord is necessary, use 12 AWG
(2.5 mm
An undersized cord results in a drop in line voltage and loss of power and overheating.
3A5575D
The following warnings apply only to 120V models
WARNING
grounded.
120V US
2
) minimum to carry the current that the product draws.
Improper grounding, setup, or usage of the system can cause
Warnings
5