APPENDIX A: SPECIFICATIONS
A termination switch on the CTP100T can be used to provide an internal
50-ohm termination at the BNC receptacle.
A.2 System Characteristics
Since the CTP100T does not retime data, the operational limits of the
CTP100T may be determined by individual system jitter.
Some Ethernet products built before 1987 cannot operate when the jitter
levels exceed 14 ns. Therefore, the CTP100T may not provide error free
operation in all Ethernet environments.
A.3 Power Specifications
Depending on the CTP100T adapter order, one of the following power
supplies is included in the shipment.
Power Supply (Domestic Version)
Input Voltage:
Output Voltage:
Output Current:
Power Supply (VDE/European Version)
Input Voltage:
Output Voltage:
Output Current:
Page A-2
100 to 125 Vac, 60 Hz
+12 Vdc
0.5Vdc
0.8 A to 1.0 A
200 to 240 Vac, 50 Hz
+12 Vdc
0.5Vdc
0.8 A
CTP100T USER'S MANUAL