8. Remove the anti-static kit.
9. Replace the cover (Figure 5-8).
10. Connect a terminal to the Access Server 316 (See section titled
on page 7-4.).
Flashing
11. Reconnect the cables and test the Access Server 316.
When you plug in the power cable, the Access Server 316 runs self-tests. After
the tests are completed, the Access Server 316 requests a load from Flash
RAM. If Flash RAM is installed, three horizontal segments will be displayed.
To abort Flash RAM load and to load from the network, press and hold the
system reset switch until the display flashes. The Seven-segment display will
alternate between 3 and 4 until the software is loaded from the network.
Allow 3 minutes for the Access Server 316 to complete the procedure.
Figure 5-8. Cover Replacement
Replacing and Adding Memory
System OK LED
5-9