Section 1 - Safety; Description Of Appropriate Use; General Safety - Universal Laser Systems M-360 Safety, Installation, Operation, And Basic Maintenance Manual

Laser engraving and cutting system
Table of Contents

Advertisement

Section 1
Safety

Description of Appropriate Use

This device is designed for laser cutting and engraving of the materials listed in this manual, in a
laboratory, workshop, or light duty manufacturing environment.
completely inside the system for proper operation.
Notice: This device is not designed, tested, intended or authorized for use in any medical
applications, surgical applications, medical device manufacturing, or any similar procedure or
process requiring approval, testing, or certification by the United States Food and Drug
Administration or other similar governmental entities. Please see the Notice herein for further
information regarding such uses.

General Safety

Use of the equipment in a manner other than what is described in this manual can result in injury to
yourself, others, or may cause severe damage to the equipment and your facility. Failure to follow the
operational requirements and safety guidelines, listed in this manual, may increase this risk.
Exposure to the laser beam may cause physical burns and can cause severe eye damage.
Proper use and care of this system are essential to safe operation.
Never operate the laser system without constant supervision of the cutting and engraving
process. Exposure to the laser beam may cause ignition of combustible materials and start a fire. A
properly maintained fire extinguisher should be kept on hand at all times.
A properly configured, installed, maintained, and operating particulate/fume exhaust system is
mandatory when operating the laser system. Fumes and smoke from the engraving process must
be extracted from the laser system and exhausted outside.
Some materials, when engraved or cut with a laser, can produce toxic and caustic fumes. We
suggest that you obtain the Material Safety Data Sheet (MSDS) from the materials manufacturer.
The MSDS discloses all of the hazards when handling or processing that material. DISCONTINUE
processing any material that shows signs of chemical deterioration of the laser system such as rust,
metal etching or pitting, peeling paint, etc. Damage to the laser system from caustic materials is NOT
covered under warranty.
Care should be taken when moving or lifting this device. Obtain assistance from 1 or 2 additional
people when lifting or carrying (secure motion system and doors). Severe bodily injury may occur if
improper lifting techniques are applied or the system is dropped.
Dangerous voltages are present within the electronics and laser enclosures of this system.
Although access to these areas is not necessary during normal use, if it becomes necessary to open
one of these enclosures for service reasons, please remember to disconnect the power cord from
your electrical supply.
This device is specifically designed to comply with CDRH performance requirements under 21
CFR 1040.10 and 1040.11. CDRH is the Center for the Devices of Radiological Health division of the
Food and Drug Administration (FDA) in the USA. It also complies with CE (European Community)
safety regulations. No guarantees of suitability or safety are provided for any use other than those
specified by Universal Laser Systems, Inc.
Materials to be processed must fit