P/N 0539221_T
REPLACING FAN MOTORS AND BLADES
For access to these fans:
1. Turn off power.
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Remove fan blade.
5. Lift fan plenum and remove screws holding
bottom of motor to fan basket.
6. Replace fan motor and blade.
7. Lower fan plenum.
8. Reconnect fan to wiring harness.
9. Turn on power.
10. Verify that motor is working and blade is
turning in the correct direction.
11. Close large air gaps under fan plenum.
Warmer air moving into refrigerated air
reduces effective cooling. If the plenum does
not rest against the case bottom without
gaps, apply foam tape to the bottom of
the fan plenum to reduce improper air
movement, however defrost water should
not be blocked by fan plenum. Do NOT
seal fan plenum so that water can not drain.
12. Replace display pans. Bring merchandiser
to operating temperature before restocking.
Hussmann recommends against frame heater
cycling with Innovator doors to prevent door
seals from freezing to the frames and tearing.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
SERVICE
Always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items
as fans, heaters, thermostats and lights.
Product will be degraded and may spoil if
allowed to sit in a
S
er vi c e # M O . X X X X X X X
XX XXXXX
non-refrigerated area.
Freedom Line Reach-in
6-1