Service - Hussmann microDS Insight ID6SU-W Installation & Operation Manual

Table of Contents

Advertisement

P/N 3074287_H
Before Beginning Any Service or Repair:
Use a hand-held propane leak detector
("sniffer") to ensure no propane is present in
the immediate area, the inside of the display
case and the inside of the refrigeration system.
Keep the area clear of all customers and
non-essential or unauthorized personnel.
Verify that all repair parts are identical models
to the ones they are replacing. Failure to do so
can result in an explosion, death, injury and
property damage.
Brazing must not begin before all propane has
been cleared from the immediate area, the in-
side of the displays case and the inside of the
refrigeration system.
If a leak is detected, follow store safety
procedures.
It is the store's responsibility to have a written
safety procedures in place. The safety proce-
dure must comply with all applicable codes
such as local fire department's codes.
At minimum, the following actions are re-
quired:
• Immediately evacuate all persons from the
store, and contact the local fire department to
advise them that a propane leak has occured.
• Call Hussmann and/or a qualified service
agent and inform them that a propane sensor
has detected the presence of propane.
• Do not let any persons back into the store
until the qualified service technician has arrived
and that technician advises that it is safe to re-
turn to the store.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

SERVICE

Only Hussmann or fac-
tory trained technicians
should service or repair
this R-290 (propane)
equipment.
Failure to follow instruc-
tions can result in an ex-
plosion, death, injury and
property damage.
• The propane gas used in the unit has no odor.
The lack of smell does not indicate a lack of
escaped gas.
• A hand-held propane leak detector
("sniffer") should be used before any repair
and/or maintenance is attempted. All repair
parts must be identical models to the ones they
are replacing.
• No open flames, cigarettes or other possible
sources of ignition should be used inside the
building where the units are located until the
qualified service technician and/or local fire
de-partment determines that all propane has
been cleared from the area and from the refrig-
eration systems.
Showcases with R-290 Refrigerant
6-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Microds insight id5sl-w

Table of Contents