Maintenance - Trane 09CO-FIXED-A1 Service Manual

Table of Contents

Advertisement

3. Maintenance

3.1 Failure code
Code
IDU Room Temperature sensor failure.
E1
(IDU RT failure)
IDU Coil temperature sensor failure.(IDU
E2
IPT failure)
E4
Gas not enough
E5
System protection
IDU PG Fan motor / DC fan motor works
E6
abnormal(IDU failure)
P7
Overheating protection on Heating mode.
Note: Remote controller FAILURE CODE Querying function
As shown in the failure codes, some of the codes (Fb~bj) need to press remote control for inspection.
While unit on operation, press the ECO button 8 times with 8 seconds, the buzzer BIBI 2 times, you can
inspect the special failure code as Fb ~Fn, bj etc.
Air Conditioner Service Manual
Reason
Remark
IDU sensor and PCB.
IDU sensor and PCB.
Please check the pressure in cooling
For the high/low pressure valve model
Fan motor, fan blade and PCB.
Please check the troubleshooting for detail.
31

Advertisement

Table of Contents
loading

Table of Contents