Startup Problems - HP E Series User Manual

Hide thumbs Also See for E Series:
Table of Contents

Advertisement

Startup problems

Table 17
describes corrective actions for problems which occur during startup.
Table 17

Startup problems

Problem
The library does not power on.
The library or tape drives are not detected by the
Interface Manager or Command View TL software.
During initialization, the library robot stops moving and
the OCP status bar is red.
Corrective action
Verify that:
The power cord is connected to a grounded
electrical outlet.
Each PDU power switch is on, as well as the switch
on the power strips.
Power cords from PDU power strips are installed and
seated.
The library main power switch is on.
Check cable connections.
Check the cabling. Ensure all radial bends do not
exceed a 2-inch diameter.
Verify that the drives and library are powered on
and can be seen by the OCP and hosts.
Check the log files for network problems.
Ensure that the interface controllers are powered on
and ready.
Check the last entry in the critical error log on the OCP.
Use the following errors as examples in correcting the
problem:
0100: Module # does not have RLP(2)
Check power to the module number. Refer to the
checks listed above under "The library does not have
power."
5501: Failed target calibration for MRC: X, X. X
Verify that nothing is obstructing the bar code
reader.
Verify the magazine is installed and seated properly.
Check for defective magazine target markings.