4.9

Air Inlet System - Air cleaner

Air cleaner supplied with the engine is Dry Type aircleaner. It consists if two filter elements - Outer & Inner
element. Outer element is the main filter element with in built cyclone separater which gives swirling effect
to incoming air, to separate out heavy dust particles.The dust is collected in evacuator valve at the bottom
of air cleaner housing.
Inner element is a 'Safety Element' to prevent entry of foreign particles & dust when Outer element has
been removed.
In case that elements are deformed, damaged or if the air cleaner has a crack, replace it. By the definite
interval, the elements must be cleaned and replaced.
-
Replace Inner Element at Every 1000 Hrs
-
Changing of air cleaner element ( OUTER ): Every 500 Hours
The intercooler is air to air type and has a large cooling fan capacity. The intercooler life and performance
depends on the intake air condition greatly. Fouled air pollutes and clogs the air fins of intercooler. As a
result of this, the engine output is decreased and engine malfunction is occurred. So you always check
whether the intake air systems like air filter element are worn or polluted.
-
Cleaning of intercooler fins: Every 500 hours at Normal site condition.
38
Air/air intercooler with
downstream radiator
(Combined radiator)
Cooling air
Hot charge air from compressor
Recooled charge air to intake
pipe (max. 50
C)