INSTALLATION INSTRUCTIONS

Read these instructions carefully and completely before you install the machine. The installation should
be carried out by a qualified technician who is familiar with all local codes and ordinances for electrical
and plumbing connections. If a commercial dishwasher is being installed in this area for the first time,
most of the cabinet work, plumbing, and electrical has to be done before moving the machine into place.
In the case of replacing an old dishwasher, check first the plumbing connections and wiring before
moving the new dishwasher into place. Reasonable access to and around the dishwasher for service
must be provided.
1. ELECTRICAL CONNECTIONS
Connect supply cable with a UL-listed strain relief bushing (if nonmetallic cable is to be used). A 208-
230 volt, 60 Hz, 1 phase for SR-04 and 3 phase for SR-04T circuit is required for this machine. Despite
the fact that the rating plate shows 220 volts, the unit is designed function properly on 208 volts to 230
volts.
1) Before working on wiring the machine, be sure the electrical power has been turned off at the
breaker/fuse box.
2) Electrical and grounding connections must comply with the applicable portions of the national
electrical code and/or other local electrical codes.
Installation Instructions
Ecomiser SR-04 / SR-04T Manual 8/25 Page Rev.06