Ecomiser SR-04 Manual page 17

Door type dishwasher
Table of Contents

Advertisement

While the power is turned OFF, press DOWN+UP+START/STOP key simultaneously for 3
seconds to initiate PCB LINE TEST MODE. Lock/Unlock temperature restriction of 82 ℃ for
rinsing tank, and 50 ℃ for washing tank.
5. Power breaker ON
1) Provides power source to the machine. (Breaker ON)
2) When power is provided, breaker will make first initial long buzzer sound.
6. OPERATION
POWER key will initiate water supply, and as the water level reaches different heaters, heaters will
be initiated. Machine will start initiation stage where water temperature will be warmed up until it
reaches the pre-set temperature.
6-1 Initiation Stage
1) If the water temperature in the rinsing tank reaches 92 ℃(198 ℉), and washing tank
reaches 55 ℃(131 ℉), initiation stage is completed.
2) Not meeting the initiation stage requirement
If the temperature in the upper level rinsing tank reaches 92 ℃(198 ℉), rinsing cycle will
initiate once, and if the temperature is below that of 92 ℃(198 ℉), cycle will not initiate
until the temperature requirement is met.
6-2 During Initiation Stage
1) Washing, Rinsing, Detergent: 10 seconds
2) Washing: 80 seconds
3) Rinsing: 10 seconds
4) If the door is opened during initiation stage, it will cancel the ongoing cycle.
5) Press POWER key to stop the whole initiation stage.
6) If initiation stage is cancelled, [RUN]/[00],[00]/[00] message will appear in 2 seconds
interval.
For example:
[run / 100]: Cycle time: 100 seconds
[65 / 90]: Washing tank temperature: 65 ℃, Rinsing tank temperature: 90 ℃
6-3 POWER OFF
1) Water will start to drain out.
- Drain pump: 90 seconds
- Rinsing pump (Cleaning process): 10 seconds
- Waiting: 10 seconds
- Drain pump re-initiation: ON (30 seconds)  OFF (5 seconds)  ON (5 seconds) 
OFF (5 seconds)  ON (5 seconds)
2) Press START/STOP key during water drain stage to stop the cycle and the machine
completely.
7. ERROR MESSAGE
1) Er1: Washing temperature sensor  If OPEN or SHORT, temperature is above 110 ℃(230 ℉)
EF1