If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before attempting
installation.
NOTE: If you are not sure if the outlet box is grounded,
contact a licensed electrician for advice, as it must be
grounded for safe operation.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connectors supplied.
NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner's Manual for
wiring.
2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 13). Securely connect the fan motor
black wire and blue wire to the supply black (hot)
wire using wire connector supplied (Figure 13). After
connections have been made, turn leads upward and
carefully push leads into the outlet box, with the
green equipment-grounding conductor and white
grounded neutral conductor on one side of the outlet
box and the black and blue ungrounded conductors
on the other side of the outlet box.
WARNING
!
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
3. Screw the two threaded studs (supplied) into the
tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 14).
5. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 14).
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan is
now wired to be turned on and off from the fan
switch.

5. How to Wire Your Ceiling Fan

BLACK AND BLUE
FAN WIRES
GROUND
WIRE
LISTED
WIRE
CONNECTOR (3)
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL
Figure 4
Figure 13
THREADED
STUDS (2)
KNURLED
KNOBS (2)
Figure 14
!
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
6. Cut the 3-speed switch pull chain to a desired length
(optional). Connect the die-cast pendant (supplied)
to the 3-speed switch pull chain by sliding the die-
cast pendant (small hole first) onto the pull chain.
Attach the chain coupling to the end of the chain and
allow the die-cast pendant to fall down over the
coupling.
Please contact 1-800-654-3545 for further assistance
9
WHITE SUPPLY
(NEUTRAL)
WHITE FAN
WIRE
BLACK SUPPLY
(HOT)
NOTE: CEILING COVER
OMITTED FOR CLARITY.
CEILING
COVER
LOCKWASHERS
(2)
WARNING