Louver Control - Fujitsu AS G07LMCA Series Service Instruction

Split type room air conditioner wall mounted type indoor unit outdoor unit inverter
Hide thumbs Also See for AS G07LMCA Series:
Table of Contents

Advertisement

7. LOUVER CONTROL

1. VERTICAL LOUVER CONTROL
(Function Range)
Each time the button is pressed, the air direction range will change as follow:
The Remote Controller's display does not change.
If you set the angle to position 4.7 for more than 30 minutes in COOL or
DRY mode, they automatically return to position 3.
In COOL or DRY mode, if the angle is set to position 4.7 for many hours,
condensation may be formed, and the drips may wet your property.
Use the air direction adjustments within the ranges shown above.
The vertical airflow direction is set automatically as shown, in accordance with the type of operation selected.
Cooling / Dry mode
Heating mode
During AUTO or Heating mode operation, for the first a few minutes after beginning operation,
air-flow will be horizontal 1; the air direction cannot be adjusted during this period.
The air flow direction setting will temporarily become 1 when the temperature of the air -flow is
low at the start of the Heating mode.
2.
ADJUST THE RIGHT-LEFT LOUVERS
Move the Right-Left louvers to adjust air flow
in the direction you prefer.
2. SWING OPERATION
To select Vertical Airflow Swing Operation
When the swing signal is received from the remote controller, the vertical louver starts to swing.
(Table11 : Swinging Range)
Cooling / Dry mode
Fan mode (
)
The SWING operation may stop temporarily when the air conditioner's fan is not operating,
or when operating at very low speeds.
To select Horizontal Airflow Swing Operation
(No function)
Horizontal flow
Downward flow
Knob
Range
01-08
1
2
3
Knob
Right-Left Louvers
Fig.9 :
Air Direction Range
4
5
6 7
Right-Left Louvers