APPENDIX
Error no.
Error
113
REFLO2_TOO_LOW
114
FALSE_FLAME
115
LOW_WATER_PRESSURE_ERROR
116
LOW_WATER_PRESSURE_SENSOR Low water pressure
117
BLOCKED_DRAIN
118
WD_COMM_ERROR
119
RETURN_OPEN
120
SUPPLY_OPEN
121
SUPPLY2_OPEN
122
DHW_OPEN
123
FLUE_OPEN
124
FLUE2_OPEN
125
OUTDOOR_OPEN
126
RETURN_SHORTED
127
SUPPLY_SHORTED
128
SUPPLY2_SHORTED
129
DHW_SHORTED
130
FLUE_SHORTED
131
FLUE2_SHORTED
132
OUTDOOR_SHORTED
133
RESET_BUTTON_ERROR
135
T_EXCHANGE_BLOCK_ERROR
136
T_CHIMNEY_OPEN
137
T_EXCHANGE1_OPEN
138
T_EXCHANGE2_OPEN
139
T_SELECTION1_OPEN
140
T_SELECTION2_OPEN
Description
Internal software error
Flame is detected in a state in which no
flame is allowed to be seen
Low water pressure error
Blocked drain switch is active
Watchdog communication error
Return sensor open
Supply sensor open
Supply2 sensor open
DHW sensor open
Flue sensor open
Flue2 sensor open
Outdoor sensor open
Return sensor shorted
Supply sensor shorted
Supply2 sensor shorted
DHW sensor shorted
Flue sensor shorted
Flue2 sensor shorted
Outdoor sensor shorted
Too many resets in a short time period
Exchange temperature exceeded 90°C
Chimney sensor open
Exchange 1 sensor open
Exchange 2 sensor open
Selection 1 sensor open
Selection 2 sensor open
53
53
Checks
Solutions
Control board replacement
Control board replacement
Control board replacement
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the return tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the supply tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the DHW tempera-
values are incorrect sensor must be
ture sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the Outdoor tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the return tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the supply tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the DHW tempera-
values are incorrect sensor must be
ture sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the Outdoor tem-
values are incorrect sensor must be
perature sensor.
replaced.
a- If the wiring is damaged, replace it;
a- Check the integrity of the
b- Verify that the temperature sensor
wire connections;
has the correct resistance values. If
b- Check the Outdoor tem-
values are incorrect sensor must be
perature sensor.
replaced.