Chapter 4. Product Description; Specifications; Test Data At A Glance - Sharp AX-1100 Service Manual

Microwave oven with steam and grill
Table of Contents

Advertisement

AX1100(R)
CHAPTER 4.
PRODUCT DESCRIPTION

[1] SPECIFICATIONS

ITEM
230 Volts
Power Requirements
50 Hertz
Single phase, 3 wire grounded
Steam cooking ---- 0.91 kW Approx. 4.0A
Grill cooking --------1.1 kW
Power Consumption
Combi cooking ---- 2.53 kW Approx. 11.4A
Microwave cooking ---- 1.51 kW Approx. 6.8A
Off mode (Energy save mode) ---- less than 0.5 W
*900 W nominal of RF microwave energy (IEC 60705 Test procedure)
Microwave Power Output
Operating frequency 2450 MHz
Grill heating element 1.05kW
Heating Element Output
Engine heating element 0.86kW
Width 520mm
Outside Dimensions
Height 331mm
Depth 500mm
Width 343mm
Cooking Cavity Dimensions
Height 210mm
Depth 381mm
Weight
Approx. 18.1kg
Manual cooking
Control Complement
Automatic cooking
* The International Electrotechnical Commission's standardized method for measuring output wattage. This test method is widely recognized.

[2] TEST DATA AT A GLANCE

PARTS
Fuse
Fuse (Noise filter)
Thermal cut-out (Magnetron)
Thermal cut-out (Oven)
Thermal cut-out (Engine)
Thermistor (Engine)
Thermistor (Grill)
Grill heating element
Engine heating element
Oven lamp
High voltage capacitor
Magnetron
High voltage transformer
WARNING: DISCONNECT THE PLUG WHEN MEASURING RESISTANCE
Approx. 4.8A
NOTE: Internal capacity is calculated by measuring maximum width, depth and height.
Actual capacity for holding food is less.
Cooking mode
Temp/power range
High
100 °C
Steam
Low
70 - 95°C
-
Grill
Grill: 100% power
High
Microwave: 10 - 70% power
Combi
Grill: 50% power
Low
Microwave: 10 - 70% power
Microwave
0 - 100% power
Steam menus
Auto grill menus
Auto defrost menus
SYMBOL
VALUE / DATA
F1
20A 250V
F2
F8A
TC1
145C Off/ -20C On
TC2
170C Off / -20C or -35C On
TC3
170C Off / -20C or -35C On
TH1
Approx. 200k at 25C/ Approx. 10k at 100C/ Approx. 1k at 200C,
TH2
Approx. 200k at 25C/ Approx. 10k at 100C/ Approx. 1k at 200C,
GH
Approx. 46.5 ~ 51.1 at 25C/ Insulation resistance > 10M
EH
Approx. 58.0 ~ 62.9 at 25C/ Insulation resistance > 10M
OL
240 - 250V 25W
C
AC 2100V 1.13F
Filament < 1 / Filament - chassis  ohm
MG
T
Filament winding < 1
Secondary winding Approx. 159.5 / Primary winding Approx. 1.98
Service Manual
DESCRIPTION
Time range
Water tank
0 - 35 min.
YES
0 - 60 min.
YES
0 - 99 min. 50 sec.
NO
0 - 99 min. 50 sec.
NO
0 - 99 min. 50 sec.
NO
0 - 99 min. 50 sec.
NO
4 – 1
AX1100(R)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ax-1100inAx-1100r