The wire which is coloured GREEN AND YELLOW must be connected to terminal
which is marked with the letter "E" or by the Earth
or GREEN AND YELLOW.
–
The wire which is coloured BLUE must be connected to the terminal which is
marked with the letter "N" or coloured BLACK.
–
The wire which is coloured BROWN must be connected to the terminal which is
marked with the letter "L" or coloured RED.
■
Refit the cable clamp so that it clamps the outer sleeving of the cable, and screw the
screws "C".
■
Refit the cover plate "B" and fix it with the screw "A".
N.B. The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
This double oven must be connected to electrical supply using V105 insulated cable.
3 x 2.5 mm
(*)
2
(*) Connection with wall box connection.
Figure 4
A
4450 W (19.34 A)
B
symbol or coloured GREEN
Figure 5
Brown (Live)
Blue (Neutral)
P
C
L
N
E
L
N
PE
1
1
(L
)
2
(L
)
2
L
N
D
Green & Yellow
(Earth)
11