ELECTRICAL REQUIREMENTS

The appliance must be connected to the mains checking that the voltage corresponds
to the value given in the rating plate and that the electrical cable sections can withstand
the load specified on the plate.
A suitable isolating switch providing full disconnection from the mains power supply
shall be incorporated in the permanent wiring, mounted and positioned to comply with
the local wiring rules and regulations. The isolating switch must be of an approved
type and provide a 3 mm air gap contact separation in all poles (or in all active [phase]
conductors if the local wiring rules allow for this variation of the requirements).
The isolating switch shall be easily accessible to the customer with the oven installed.
The power supply cable must not touch the hot parts and must be positioned so that it
does not exceed 75°C above ambient.
To connect the appliance to the mains electricity supply, do not use adapters, reducers
or branching devices as they can cause overheating and burning.
If the supply cord is damaged it must be replaced by the manufacturer or it's Service
Agent or a similarly qualified person in order to avoid a hazard.
N.B. The connection of the appliance to earth is mandatory.
If the installation requires alterations to the domestic electrical system call a qualified
electrician. He should also check that the domestic electrical system is suitable for the
power drawn by the appliance.
Connecting / replacing the power cord must be done by a qualified electrician in
accordance with the instructions supplied by the manufacturer and in compliance
with established electrical regulations.

CONNECTING THE POWER SUPPLY CABLE

Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
Unscrew the screw "A" securing the cover plate "B" behind the oven (fig. 4).
Remove the cover plate "B".
Remove the screws "C" from the cable clamp (fig. 5).
Insert the mains cable (type V105 - 3 x 2,5 mm
Connect the phase, neutral and earth wires to the mains terminal connection block "D".
The wires of this appliance must be coloured in accordance with the following code:

GREEN AND YELLOW - EARTH

BLUE - NEUTRAL - "N"

BROWN - LIVE - "L"